STANDARD OR ANGLE MOUNTING INSTRUCTIONS
4. Depending on the length of downrod you use, you
may need to cut the lead wires back to simplify the
wiring. If you decide to cut back the lead wires, it is
suggested you do so in the following manner: Take
the lead wires and make sure you have pulled them
all the way through the top of the downrod. Measure
8 inches of lead wire, then cut the excess wire o󰀨 with
wire cutters (not included).
5. If you decided to cut back the lead wire in Step 4, strip
1/2 in. of insulation from the end of the white wire.
Twist the stripped ends of each strand of wire within
the insulation with pliers (not included). Repeat the
step for the black wire.
Note: If you did not cut back the lead wires in Step 4,
Step 5 is not necessary and you may proceed to Step
6 instead.
6. Install the ball end of the downrod (A) into the opening
of the mounting bracket (D). Align a slot in the ball
with the tab in the mounting bracket (D).
Important: The downrod (A) should not rotate in the
mounting bracket (D) if installed properly.
DANGER: Failure to align a slot in the ball with
the tab may cause the fan to wobble or fall, which
could result in serious injury or death.
5
A
D
Tab
Slot
6
4
8 in.
Loading ...
Loading ...
Loading ...