Loading ...
Loading ...
Loading ...
21
bromic.com/heating-au
OPERATING INSTRUCTIONS
MAX
OFF
TURNING THE APPLIANCE ON
1. Ensure that installation has been carried out in accordance
with the manufacturers instructions outlined in this document.
2. Test the spark ignite button is working correctly by pressing the
button and observing sparks at the ignition rods at the front of the
heater. If sparks are not observed do not proceed with turning appli-
ance on. Contact the store of purchase for assistance and advice.
TURNING THE APPLIANCE OFF
1. Press and turn the control knob to “OFF” position to stop the supply
of gas to the burner. The tiles should change colour from red to black.
2. Turn OFF the gas supply at the LPG storage bottle.
3. WARNING - After turning heater off, you must wait a minimum 5 minutes
to let excess gas dissipate before lighting again.
3. Turn ON the gas supply at the LPG storage bottle.
4. Turn on gas control knob to maximum setting
6. When appliance is correctly turned on the tiles
will start to glow red.
5. Push in and hold control knob whilst simultaneously press-
ing the spark ignite button. Continue to hold in the controls for
10 seconds for ignition to complete.
Release the controls. If the heater has not ignited wait
5 minutes and then repeat Step 5.
WARNING
Do not turn the heater on with people standing in front of heater.
Heater must be turned on while standing behind the heater.
WARNING
Improper lighting procedures can cause personal injury, property
damage, or even death.
MAX
OFF
!
!
Loading ...
Loading ...
Loading ...