Loading ...
Loading ...
Loading ...
20
bromic.com/heating-au
LEAK TEST
Gas connections on heater are leak tested at the factory
prior to shipment. A complete gas leak test must also be
performed after assembly before operating the heater due
to possible damage occurring during transportation.
• Never leak test while smoking.
• The heater must be checked with a full gas cylinder.
• Ensure connection all 3 connections illustrated below are
connected correctly & tight.
• Make sure the control knob is in the OFF position.
• Make a mild soapy water solution. The soapy solution can be
applied with a spray bottle, or soft cloth.
• Turn on the gas supply at the gas cylinder.
• Apply the soapy water solution to the 3 connections illustrated
below.
• To check connection #3 the gas control knob must be pressed
in to open the gas valve.
• If bubbles appear at any of the connections, there is a gas leak.
• If a gas leak is detected, turn off the gas supply. Tighten any
leaking fittings, and repeat process described above.
• If soap bubbles still appear (gas is still leaking), turn
off the gas supply at the cylinder, disconnect the regulator
from the gas cylinder, and contact the store of purchase for
assistance and advice.
• If gas connections are gas tight, the heater is ready to
be used.
INSTALLATION INSTRUCTIONS CONTINUED...
3
1
2
Loading ...
Loading ...
Loading ...