4
INSTALLATION REQUIREMENTS
Tools and Parts
Gather the required tools and parts before starting installation. Read
and follow the instructions provided with any tools listed here.
Tools needed
Level
Drill with 1¼" (3 cm), 3/8" (9.5 mm), 7/64" (2.75 mm) and
1/8" (3 mm) drill bits
Pilot hole drill bits (determined by chimney support attachment
method)
Pencil
Wire stripper or utility knife
Tape measure or ruler
Pliers
Caulking gun and weatherproof caulking compound
Vent clamps
Jigsaw or keyhole saw
Flat-blade screwdriver
Metal snips
Phillips screwdriver
Ladder
Hacksaw
Parts needed
Home power supply cable
1/2" (12.7 mm) UL listed or CSA approved strain reliefs (2)
UL listed wire connectors (3)
For vented installations, you will also need:
Wall or roof cap
Metal vent system
For non-vented (recirculating) installations, you will also need:
Recirculating Kit for non-vented (recirculating) installations only.
See “Assistance or Service” section to order.
6" (15.2 cm) round metal vent duct. Length required is
determined by ceiling height.
Parts Supplied
Remove parts from packages. Check that all parts are included.
Ø4x8 mm
Ø8x40 mm Ø5x45 mm Ø3.5x9.5 mm Ø2.9x6.5 mm
Location Requirements
IMPORTANT: Observe all governing codes and ordinances.
Have a qualied technician install the hood. It is the installer's
responsibility to comply with installation clearances specied
on the model/serial/rating plate. The model/serial rating plate is
located behind the left lter on the rear wall of the vent hood.
Canopy hood location should be away from strong draft areas,
such as windows, doors and strong heating vents.
Cabinet opening dimensions that are shown must be used.
Given dimensions provide minimum clearance.
Grounded electrical outlet is required. See “Electrical
Requirements” section.
Because of the size and weight of this wall hood, the chimney
support must be securely attached to the wall.
For plaster or drywall ceilings, the chimney support must be
attached to joists. If this is not possible, you must build a
support structure behind the plaster or drywall. The support
structure must be able to support 100 lbs (45.4 kg).
IMPORTANT: The means of xing supplied with the hood, are
exclusively suitable for xing on concrete or brick ceiling.
Ask a qualied technician to indicate which fasteners should be
used depending on the type of wall/ceiling in the home.
For the various wall or ceiling mounted installations, use screws
and dowels suited to the type of structural material (e.g. cement,
wood, etc.).
Check that the screws and dowels supplied with the product
are suited to the type of wall/ceiling on which the hood will be
mounted.
A qualied technician must ensure the wall/ceiling where the
hood will be installed is solid enough to support the weight of
the product.
If not, prepare a suitable frame for said purpose.
This hood is recommended for use with cooktops with a
maximum total rating of 90,000 BTUs or less on 600 CFM models
and 62,000 BTUs or less on 400 CFM models.
The hood is factory set for venting thr
ough the roof.
For non-vented (recirculating) installation, see “Non-vented
(recirculating) Installations” in “Assemble and Install Hood”
section. Recirculation Kit Part Number W11522798 is available
from your dealer or an authorized parts distributor.
All openings in ceiling and wall where hood will be installed must
be sealed.
For Mobile Home Installations
The installation of this hood must conform to the Manufactured
Home Construction Safety Standards, Title 24 CFR, Part 328
(formerly the Federal Standard for Mobile Home Construction
and Safety, Title 24, HUD, Part 280) or when such standard is
not applicable, the standard for Manufactured Home Installation
1982 (Manufactured Home Sites, Communities and Setups) ANSI
A225.1/NFPA 501A, or latest edition, or with local codes.
Product Dimensions
G
F
E
D
C
B
A
A. 12
7
/
16
" (31,6 cm)
B. 12
7
/
16
" (32 cm)
C. 29
15
/
16
" (76 cm)
35
6
/
16
" (89,6 cm)
D. 17
1
/
16
" (43.4 cm)
E. 2
6
/
16
" (6.0 cm)
F. 26
12
/
16
" (67.9 cm)
G. **27
15
/
16
" (71.0 cm) minimum
***47
4
/
16
" (120.0 cm) maximum
*Vented installations only
**Non-vented (recirculating) installations only