11. CLI Commands
11.4.11 Configuring EDID Mode
To set the EDID mode of a specified B162-001-POE transmitter, type the command in this format:
edid + i<port> + <EDID_mode> + \r\n
Control Description
i<port> Indicates the device ID, MAC address or IP address of the transmitter
(B162-001-POE) connected to the source of the target display.
<EDID_mode> Indicates the EDID mode you wish to set to the specified transmitter. Valid
inputs include:
Default – Sets up the input to an optimum configuration based on EDID
predefined by Tripp Lite.
Auto – Sets up the input to the highest resolution of the connected displays.
• Manual – Sets up the input to user’s configuration.
Remix –
Sets up the input to an optimum resolution of the connected displays.
\r\n Ends the command.
Example:
• To set the EDID mode of a transmitter with the device ID of 16 to auto, type edid i016 auto
11.4.12 Rebooting the B162 Units
To reboot a B162 transmitter or receiver, type the command in this format: reset + a<port> | i<port> |o<port> + \r\n
Control Description
a<port> Indicates the device ID or IP address of the target transmitter or receiver.
i<port> Indicates the device ID of the target input device (B162-001-POE).
Use an asterisk (*) to target all transmitters in the environment.
o<port> Indicates the device ID of the target output device (B162-100-POE).
Use an asterisk (*) to target all receivers in the environment.
\r\n Ends the command.
Example:
• To reboot the transmitter with the IP address of 10.0.60.13, type reset i10.0.60.13 or reset a10.0.60.13
• To reboot all receivers, type reset o*