Fault Cause and troubleshooting
E:18 or indicator for
water supply lights up.
The flow rate must be at least 10 l/min when the
water supply is open.
Filter in the water supply is blocked.
1. Switch off the appliance.
2. Pull out the mains plug.
3. Turn off the water tap.
4. Unscrew the water connection.
5. Remove the filter from the supply hose
6. Clean the filter.
7. Re-insert the filter in the supply hose.
8. Screw the water connection back on.
9. Check the water connection for leaks.
10. Restore the power supply.
11. Switch the appliance on.
E:22 lights up.
1
Filters are soiled or blocked.
▶ Clean the filters.
→"Cleaning filters", Page42
E:24 lights up. Wastewater hose is blocked or kinked.
1. Reposition the wastewater hose without kinks.
2. Remove residues.
Siphon connection is still sealed.
▶ Check the connection to the siphon and open if ne-
cessary.
Cover of the wastewater pump is loose.
▶ Secure the cover of the Wastewater pump
→Page55 so it clicks into position.
E:25 lights up. Wastewater pump is blocked.
▶ Clean the wastewater pump.
→"Clean wastewater pump", Page55
Cover of the wastewater pump is loose
1
Depending on the appliance specifications