When the ambient temperature is likely to drop to 32 °F (0 °C) or lower, take measures to prevent freezing.
Attention!
•
When the ambient temperature is likely to drop to 32 °F (0 °C) or lower, do not use the energy saver feature. (May damage the product.)
•
Warm the bathroom or take measures against freezing so that the ambient temperature does not drop below 32 °F (0 °C).
How to freeze damage prevention
1
Close the shutoff valve.
(Page 32 Step
1
)
•
The water supply stops.
CAUTION
Do not remove the water fi lter drain
valve while the shutoff valve is open.
(Otherwise, water may leak out.)
2
Drain the water from the toilet tank.
•
Manipulate the lever/button/etc. until the water
stops.
3
Press
"Wand CLEAN" button.
(Release the pressure from the water supply
pipe.)
4
Unplug the power plug.
5
Drain the pipe.
(1)
Remove the cover and water fi lter drain valve.
•
Loosen the water fi lter drain valve with a
fl at-head screwdriver and then pull it.
Water Filter
Drain Valve
Flat-head screwdriver
Cover
(2)
Drain the water from the water supply hose.
Water supply hose
Horizontally
(3) After draining the water, install the water
fi lter drain valve and cover.
•
Insert the water fi lter drain valve and use a
fl at-head screwdriver to tighten it securely.
Cover
6
Insert the power plug.
•
The "Power" LED lights up.
7
Set the toilet seat temperature
to "High".
(Page 20)
•
To maintain the temperature, close the toilet seat
and toilet lid after fi nishing work.
■
To use the product again
•
The water needs to be resupplied. (Page 42)
Freeze Damage Prevention