Us Stove 2500 WOODSTOVE

Owner’s Operation and Instruction Manual - Page 6

For 2500. Also, The document are for others US Stove models: 2000

PDF File Manual, 20 pages, Read Online | Download pdf file

2500 photo
Loading ...
Loading ...
Loading ...
6 Ussc
FLOOR PROTECTOR
Yourwoodstoveshouldbeplacedona1inch,non-combustiblesurfacewithakfactorof0.84.For
multiplelayers,addR-valuesofeachlayertodeterminetheoverallR-value.TheRvalueforthe
requiredboardis1.2.Theoorprotectorshouldbeunderthestove,twenty-sixinchesbeyondthefront
andsixinchesbeyondeachsideofthefuelloadingandashremovalopening.Ifthereisahorizontal
sectionofchimneyconnector,theoorprotectorshouldgounderitandtwoinchesbeyondeachside
ConvertspecicationtoR-value:
k-factorisgivenwitharequiredthickness(T)ininches:R=1/kxT
C-factorisgiven:R=1/C
Example:
If the oor protector is 4” brick with a C-factor of 1.25 over 1/8” mineral board with a “k”
factor of0.29thetotalR-valueofthesystemis:
4”brickC=1.25,R=1/1.25=0.8
1/8”mineralboardK=0.29,R=1/0.29x0.125=0.431
TotalR=Rbrick+Rmineral=0.8+0.431=1.231
TotalRisgreaterthan1.2,thesystemisacceptable.
Theoorprotectorshouldexceedthestoveasfollows:
Model Front Sides Rear
2000 25” 8” 6”
2500 26” 8” 6”
Loading ...
Loading ...
Loading ...