10.1.4 Additional grease/oil points
See Figures 11-4 and 11-5.
10.2 Additional servicing
Any additional servicing should be performed by
authorized service personnel.
10.3 Lubrication recommended schedule
Item or location Recommended lubricant Frequency
Vise lead screw Light machine oil Monthly
Hydraulic cylinder pivot
areas
Light machine oil Every 6 months
Blade tension screw General purpose grease Every 6 months
Blade brush bearing Light machine oil Monthly
Gear box
Mobil
®
SHC Gear Oil 460, or
equivalent multi-purpose gear
oil
Check periodically; top off as needed.
Change after first 50 hours of operation; then at least
once a year (more frequently if heavily used).
Cutting fluid/coolant
(May vary based upon
operating needs)
Check level and fluid quality periodically. For flush
and refill schedule, refer to cutting fluid/coolant
supplier’s instructions.
Hydraulic oil
Mobil DTE
®
Excel Series 32
(or equivalent ISO 32)
Check periodically; top off as needed.
Change every 1 to 2 years or after 3000 operating
hours, whichever comes first.
Grease fitting, front of
column (Figure 11-4)
Mobil Mobilux® 1, or
equivalent.
Monthly
Grease fitting, center of
driven wheel (Figure 11-4)
Mobil Mobilux® 1, or
equivalent.
Monthly
Grease fitting at gear
shaft (Figure 11-5)
Mobil Mobilux® 1, or
equivalent.
Monthly
Table 3