Warning and Safety instructions
13
The door springs must be evenly adjusted on both sides. They are
correctly adjusted when the door remains stationary when left half
open (approx. 45° opening angle). The door must not fall open on its
own beyond this point.
The appliance must only be operated with properly adjusted door
springs.
If the door cannot be adjusted properly, contact Miele customer
service.
The maximum weight of the front panel that can be aligned with the
factory fitted door springs is 10–12kg (depending on model).
Correct use
Do not use solvents in the dishwasher. There is a danger of
explosion.
Do not inhale or ingest dishwasher detergent. Some dishwasher
detergents are strongly alkaline and contain irritants or corrosive
ingredients. They can be extremely dangerous if swallowed, and can
cause burning in the eyes, nose, mouth, and throat, or inhibit
breathing. Avoid contact with the skin and eyes. Do not inhale
powder detergents. Do not swallow dishwasher detergents. Seek
medical advice immediately if detergent has been swallowed or
inhaled. Contact a Poisons Information Centre (Australia) or the
National Poisons Centre (NZ).
Avoid leaving the dishwasher door open unnecessarily. You could
injure yourself on the open door or trip over it.
Do not sit, stand, or lean on the open door. The dishwasher could
tip over. This could injure you or damage the dishwasher.
Dishes may be very hot at the end of the programme. Allow the
dishes to cool until they are comfortable enough to handle before
unloading them.
Only use detergent and rinse aid formulated for domestic
dishwashers. Do not use washing-up liquid.