Electrical Precauons
WARNING! Failure to follow these instrucons could result in property damage, personal injury
or death.
230 - 240V / AC - 50HZ – 0.4A.
To protect against electric shock, do not immerse cord or plugs in water or other liquid.
Unplug from the outlet when not in use and before cleaning. Allow to cool before pung on or
taking o parts.
Do not operate any outdoor cooking gas appliance with a damaged cord, plug, or aer the appli-
ance malfuncons or has been damaged in any manner. Contact the manufacturer for repair.
If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a
similarly qualied person in order to avoid a hazard.
Do not let the cord hang over the edge of a table or touch hot surfaces.
Do not use an outdoor cooking gas appliance for purposes other than intended.
When connecng, rst connect plug to the outdoor cooking gas appliance then plug appliance into
the outlet.
Use only a Ground Fault Interrupter (GFI) protected circuit with this outdoor cooking gas appliance.
Never remove the grounding plug or use with an adapter of 2 prongs.
Use only extension cords with a 3 prong grounding plug, rated for the power of the equipment, and
approved for outdoor use with a W-A marking.
Leak Tesng Instrucons
WARNING! A leak test must be performed annually and each me a cylinder is hooked up or if a
part of the gas system is replaced.
WARNING! Never use an open ame to check for gas leaks. Be certain no sparks or open ames
are in the area while you check for leaks. Sparks or open ames will result in a re or explosion,
damage to property, serious bodily injury, or death.
Leak tesng: This must be done before inial use, annually, and whenever any gas components are
replaced or serviced. Do not smoke while performing this test, and remove all sources of ignion. See
Leak Tesng Diagram for areas to check. Turn all burner controls to the o posion. Turn gas supply valve
on.
Brush a half-and-half soluon of liquid soap and water onto all joints and connecons of the regulator,
hose, manifolds and valves.
Bubbles will indicate a gas leak. Either ghten the loose joint or have the part replaced with one
recommended by the Napoleon Customer Soluons department and have the grill inspected by a cered
gas installer.
If the leak cannot be stopped, immediately shut o the gas supply, disconnect it, and have the grill
inspected by a cered gas installer or dealer. Do not use the grill unl the leak has been corrected.
!
!
!