Napoleon BIPRO665RBNSS-3-CE BUILT-IN GAS GRILL

User manual - Page 6

For BIPRO665RBNSS-3-CE. Also, The document are for others Napoleon models: BIPRO 665-3*

PDF File Manual, 68 pages, Read Online | Download pdf file

BIPRO665RBNSS-3-CE photo
Loading ...
Loading ...
Loading ...
6
EN
www.napoleon.com
N415-0542CE-GB-DE FEB 01.22
CYLINDER SIZE OPENING A AREA OPENING B AREA
20 lb (9.1kg)
20in
2
(130cm
2
) 10in
2
(65cm
2
)
30 lb (13.6kg)
30in
2
(195cm
2
) 15in
2
(100cm
2
)
127mm
MAXIMUM
25.4mm
MAXIMUM
OPENING
A
OPENING
B
51mm
MINIMUM
PARTITION TO ISOLATE
CYLINDER FROM GRILL
NON LOCKING DOOR
864mm
RECOMMENDED
127mm
MAXIMUM
Gas Hook-Up Instrucons
WARNING! This grill is designed for non-combusble enclosures only, and must be installed and
serviced by a qualied installer to local codes.
WARNING! Cabinet frame, cabinet, and counter top must be made from non-combusble
material.
WARNING! The pressure supplied to the grill must conform to what is listed on the rang plate of
the grill. If the supply pressure is greater, a regulator must be installed.
BUILT IN PROPANE GAS HOOK-UP: The piping up to the gas grill is the responsibility of the installer and
piping should be located as shown in the built-in instrucons. A exible metal connector is included to
simplify the installaon of the unit. Connect this exible metal connector to the are ng on the end of
the manifold. Connect the other end of the connector to the gas piping. Ensure that the connector does
not pass through a wall, oor, ceiling or paron, and is protected from damage. Do not use a hose to
connect the unit except to connect the cylinder regulator to the piping system. It must be connected with
rigid pipe, copper tube or an approved exible metal connector which complies with naonal and regional
codes.
The installaon must comply with naonal and regional codes. The gas supply pipe must be suciently
sized to supply the kW input specied on the rang plate, based on the length of the piping run. If
installing a side burner, a separate line must be branched o to the side burner unit and enter the side
burner opening at the specied locaon. If the enclosure is to house a propane cylinder, the tank poron
of the enclosure must be venlated according to local codes, and must not have communicaon with the
cavity used to enclose the gas grill. A propane cylinder can not be stored below the gas grill.
BUILT IN CYLINDER ENCLOSURES: Built in cylinder enclosures which completely enclose the cylinder must
have both of the following:
1. At least one unobstructed venlaon opening on the exposed exterior side of the enclosure located
within 127mm of the top of the enclosure. The opening must have a total free area of more than 130 cm
2
for a cylinder up to 9 kg and 195 cm
2
for a cylinder larger than 9 kg.
2. At least one venlaon opening on the exposed, exterior side of the enclosure located 25.4 mm or less
from the oor level. The opening must have a total free area of more than 65 cm
2
for a cylinder up to 9 kg
and 100 cm
2
for a for a cylinder larger than 9 kg. The upper edge must be no more than 127 mm above the
oor level.
Every opening must be large enough to permit the entrance of a 3.2 mm rod.
!
Loading ...
Loading ...
Loading ...