— 16 —
Maintenance
u
Make sure the range hood is unplugged or turn OFF
breaker.
v
Remove lters. Use a screwdriver to pry the light out
along the edge of the lamp.
CAUTION: PUCK MAY BE HOT, PLEASE TAKE
OUT THE PUCK WHEN THE PUCK IS
COMPLETELY COOL!
w
Slightly pull out the LED light and light connecting
wire, and disconnect the light wire.
x
Replace with a 10.2 Volt, 2.5 Watt max, LED lights.
Plug in new puck and push back into light panel.
y
Turn ON breaker and range hood to test for
operation.
Replacing the Light Pucks
IMPORTANT:
ALWAYS SWITCH OFF THE ELECTRICITY SUPPLY AT THE MAIN PANEL BEFORE CARRYING OUT ANY OPERATION
ON THE APPLIANCE.
Figure #8
Cleaning Filters
IMPORTANT: Drain oil from bafes, spacers, lters, oil tunnels, oil containers before oil and residue overow!
• Removeallbafes,spacers,lters,greasetray,andoilcontainersanddiscardoilandresidue.
• Washwithwarmsoapywater.NOTE:Stainlesssteelbafes,spacersandoiltunnelaretoprackdishwashersafe.
• Dry thoroughly before replacing and follow directions for installation in reverse.
• Filters should be cleaned after every 30 hours of use.