6
EN
www.napoleon.com
N415-0526CE-GB-DE JUL 11.20
WARNING!
• Do not route hose underneath drip pan.
• Do not route hose between space in boom shelf and back panel.
• Do not route hose over top of back panel.
• Ensure all connecons are ghtened using two wrenches. Do not use Teon tape or pipe dope on
any hose connecon.
• Ensure the hose does not contact any high temperature surfaces, or it may melt and leak causing
a re.
• Do not use enclosure to store excess hose, as there is a greater chance of the hose contacng a
hot surface, it may melt and leak causing a re.
Technical Data
Burner Orice Size (Gross) Heat Input (Total) Gas Usage (Total)
Main #60 1.45mm 19.0 kW
Rear 1.25mm #50 5.5 kW
Side (Infra Red) #58 4.0 kW
Smoker #67 #56 2.5 kW
Gas Category
I
3B/P(30)
I
3+(28-30/37)
I
3B/P(37)
I
3B/P(50)
I
2H
I
2E
I
2E+
Orice
Sizes(see
above)
Gases / Pres-
sures
Butane and
Propane at
30mbar
Butane
28-30mbar
Propane
37mbar
Butane and
Propane at
37mbar
Butane and
Propane at
50mbar
G20 at 20mbar
mbar
Countries
BE, BG, CY, DK,
LT, LU, MT, NL,
SK, TR
ES, FR, GB, GR,
PL
DE, LU, PL BE,FR
!