28
Sanitizing
14) To ll the water tank, turn the cleaning valve to the right until completely horizontal
(closed). Move the control switch to the "ICE" position, then replace the front panel.
After 3 min., remove the front panel, then move the control switch to the "OFF" position.
15) Remove the front insulation panel, then pour .78 . oz. (23 ml) of an 8.25% sodium
hypochlorite solution (chlorine bleach) into the water tank. Replace the front insulation
panel. Turn the cleaning valve to the left until completely vertical (open). IMPORTANT!
Use regular bleach with no additives. Using a bleach with additives causes
excessive foaming during sanitizing, reducing the effectiveness of sanitizing.
16) NOTICE! To avoid excessive foaming, wait 1min. before proceeding.
After 1 min., move the control switch to the "WASH" position, then replace the front
panel.
17) After 45 min., remove the front panel, then move the control switch to the "OFF"
position.
18) Remove the front insulation panel, then remove cube guide B and cube guide A.
Remove the overow cap, overow pipe, water shield, and drain plug. After the water
tank has drained, replace the drain plug, water shield, overow pipe, overow cap, cube
guide A, cube guide B, and front insulation panel.
Sanitizing Rinse 1
19) Turn the cleaning valve to the right until completely horizontal (closed). Move the control
switch to the "ICE" position, then replace the front panel. After 3 min., remove the front
panel, then move the control switch to the "OFF" position.
20) Turn the cleaning valve to the left until completely vertical (open). Move the control
switch to the "WASH" position, then replace the front panel. After 5 min., remove the
front panel, then move the control switch to the "OFF" position.
21) Remove the front insulation panel, then remove cube guide B and cube guide A.
Remove the overow cap, overow pipe, water shield, and drain plug. After the water
tank has drained, replace the drain plug, water shield, overow pipe, overow cap, cube
guide A, cube guide B, and front insulation panel.
Sanitizing Rinse 2
22) Turn the cleaning valve to the right until completely horizontal (closed). Move the control
switch to the "ICE" position, then replace the front panel. After 3 min., remove the front
panel, then move the control switch to the "OFF" position.
23) Turn the cleaning valve to the left until completely vertical (open). Move the control
switch to the "WASH" position, then replace the front panel. After 5 min., remove the
front panel, then move the control switch to the "OFF" position.
24) Remove the front insulation panel, then remove cube guide B and cube guide A.
Remove the overow cap, overow pipe, water shield, and drain plug. After the water
tank has drained, replace the drain plug, water shield, overow pipe, overow cap, cube
guide A, cube guide B, and front insulation panel.