LG Electronics DLE3400V Clothes Dryers Electric & Gas Dryers

User Manual - Page 24

For DLE3400V.

PDF File Manual, 49 pages, Download pdf file

Loading ...
Loading ...
Loading ...
24
INSTALLATION
2
Press and hold the Wrinkle Care and Temp.
buttons and then press the Power button.
(On models with a glass touch control panel,
press the Power button then IMMEDIATELY
press and hold the Temp. and Wrinkle Care
buttons.) This button sequence activates the
installation test. The code 1N will display if the
activation is successful.
3
Press the START/PAUSE button.
The dryer will start the test, which will last
a few minutes. The heat will be turned on
and the temperatures in the drum will be
measured.
4
Check the display for results.
During the test cycle, monitor the Flow
Sense™ display on the control panel. If
the Flow Sense™ LED has not turned on
when the cycle ends, the exhaust system is
adequate. If the exhaust system is severely
restricted, the Flow Sense™ LED will turn on.
Other problems may also be shown with error
codes. See the chart on the next page for error
code details and solutions.
5
End of cycle.
At the end of the test cycle, O will display. The
test cycle will end and the dryer will shut off
automatically after a short delay.
Check the Duct Condition
If the Flow Sense™ LED is turned on, check
the exhaust system for restrictions and damage.
Repair or replace the exhaust system as needed.
NOTE
When the dryer is first installed, this test
should be performed to alert you to any
existing problems with the exhaust duct in
your home. However, since the test performed
during normal operation provides more
accurate information on the condition of the
exhaust duct than the installation test, the
number of bars displayed during the two tests
may not be the same.
Do not interrupt the test cycle, as this could
result in inaccurate results.
Even if no bars are displayed during the test
cycle, some restrictions may still be present
in the exhaust system. Refer to the Venting
the Dryer section of this manual for complete
exhaust system and venting requirements.