such as compressors or fans.
Before carrying out Decommissioning procedure, it is essential that the
technician is completely familiar with the equipment and all its detail. It is
recommended good practice that all refrigerants are recovered safely. Prior to the
task being carried out, an oil and refrigerant sample shall be taken in case analysis
is required prior to reuse of recovered refrigerant. It is essential that electrical
power is available before the task is commenced
When removing refrigerant from a system, either for servicing or decommissioning,
it is recommended good practice that all refrigerants are removed safely.
The recovery equipment shall be in good working order with a set of instructions
concerning the equipment that is at hand and shall be suitable for the recovery of
all appropriate refrigerants including. when applicable, FLAMMABLE
REFRIGERANTS
The recovered refrigerant shall be returned to the refrigerant supplier in the correct
recovery cylinder, and the relevant waste transfer note arranged. Do not mix
refrigerants inrecovery units and especially not in cylinders
Warning: Risk of fire / flammable materials, taking care to avoid causing a fire by
igniting flammable material.
The maximum loading of each type of shelf is 8kg.
The ambient temperature and humidity conditions of the show case climate class
following the tab below
Test room
Climate class
Dry bulb
Temperature
Relative
Humidity %
Dew
point
Water vapour
Mass in dry air
g/kg
0 20 50 9.3 7.3
1 16 80 12.6 9.1
8 23.9 55 14.3 10.2