Blue Seal Evolution E47-7 Series 450mm Electric Pasta Cooker

Installation Operation Manual - Page 16

For E47-7.

PDF File Manual, 19 pages, Read Online | Download pdf file

E47-7 photo
Loading ...
Loading ...
Loading ...
14
This section provides an easy reference guide to the more common problems that may occur during the
operation of your equipment. The fault finding guide in this section is intended to help you correct, or at
least accurately diagnose problems with your equipment.
Although this section covers the most common problems reported, you may encounter a problem not
covered in this section. In such instances, please contact your local authorised service agent who will
make every effort to help you identify and resolve the problem. Please note that the service agent will
require the following information:-
The Model Trade Name and the Serial Number of the Appliance. (both can be found on the
Technical Data Plate located on the appliance.
Elements do not heat up. Check the mains power is supplied
to the unit and that a circuit
breaker or fuse has not tripped /
blown.
Check that the element is in the
Downposition and that the tilt
microswitch is closed.
Check that the thermostat setting
is correct and that the control
knob is set to the 'ON' position.
Turn ONthe power. Reset the
circuit breaker or replace the
blown fuse.
Adjust the microswitch so that the
microswitch is activated when the
element is fully down in the flat
(heating position).
Replace the thermostat.
Call service provider.
Over-temperature thermostat cuts
out.
Over-temperature thermostat
faulty.
Control thermostat not
maintaining set temperature.
a. Thermostat out of calibration.
b. Thermostat does not open on
temperature rise.
If the element cuts out and the
power indicator light also drops
below 100ºC, replace the
overtemperature thermostat.
Check continuity through the
thermostat leads, on temperature
rise. If circuit does not open,
replace the thermostat.
Call service provider.
Loading ...
Loading ...
Loading ...