Klein CL320KIT Tools HVAC Kit for HVAC Testing; Digital Clamp Meter, Non-Contact Voltage Tester, and Infrared/Probe Thermometer

User Manual - Page 16

For CL320KIT.

PDF File Manual, 56 pages, Read Online | Download pdf file

CL320KIT photo
Loading ...
Loading ...
Loading ...
16
ENGLISH
OPERATING INSTRUCTIONS
TEMPERATURE
1. Insert K-type thermocouple into the VΩµA
5
and COM
4
jacks
(observe polarity markings on thermocouple and meter), and rotate
function selector switch
2
to the Temperature setting.
NOTE: The meter defaults to Fahrenheit scale in this mode. To enter
Celsius scale, press the "SELECT" button
12
once. Ensure that the
appropriate icon (either
°F
or
°C
) appears on the display.
2. To measure temperature, make contact between the
thermocouple tip and the object being measured. When
thermocouple tip and object are in thermal equilibrium, the
measurement on the display will stabilize.
Remove thermocouple before switching meter to other
measurement functions.
The thermocouple included with the original purchase is
suitable for temperatures below 446°F / 230°C only.
To measure higher temperatures, a K-type thermocouple
with the appropriate measurement range should be used.
K-Type
Thermocouple
Loading ...
Loading ...
Loading ...