7. Operating Instructions
7.4 Setting the Target Humidity
The target humidity of the room to be treated can be set
from 10–95%. To set the target humidity level, press the
increase (11) and decrease (9) value buttons as
appropriate while the device is switched on. The display
screen (10) displays the chosen percentage. When the
desired level is reached, allow the display to stop ashing
to save the target value.
Once a target humidity value has been set, the
dehumidier will run until that level has been reached. If
the humidity level rises by 3% above the set level, the
unit will automatically resume operation until the
congured level is reached again.
The recommended target humidity for a typical room is
50–70%.
Important: If the target humidity level is set at a value
lower than is achievable in the climate in which it is used,
the dehumidier will operate continuously.
7.5 Using the Timer
The dehumidier can be programmed to switch either on
or o after a dened number of hours. If a value is set for
both on and o timers, the unit will cycle between on and
o according to the congured intervals.
To enable the timer, press the timer button (14) and use
the increase (11) and decrease (9) value buttons to set
the number of hours until the unit switches on or o. The
chosen value is shown on the display screen (10). When
the desired number of hours is reached, allow the display
to stop ashing to save the target value.
If the timer is set while the unit is in standby mode, the
timer will determine the number of hours until the
dehumidier automatically switches on.
If the timer is set while the unit is switched on, the timer
will determine the number of hours until the dehumidier
automatically switches o (unless the water tank is lled
before this period expires).
7.6 Auto-Defrost Functionality
When used for extended periods or in lower ambient
temperatures, frost may accumulate on the evaporator
coils, reducing the airow within the unit. When this
occurs, the dehumidier will automatically enter Defrost
mode.
When Defrost mode is enabled, the compressor switches
o but the fan continues to run.
When the dehumidier has completed the defrosting
process, it will automatically resume operation with the
previously congured settings.
Important: DO NOT switch o the machine or
disconnect it from mains power during defrosting.
7.7 Overheating Protection
The dehumidier is tted with overload and overheating
protection functions
If sudden power loss to the unit occurs during operation,
the unit will shut down for three minutes to protect the
compressor and will not run during this period. If power
is reconnected, the dehumidier will resume operation
once this time has elapsed.
If the temperature of the coolant circuit coil rises
abnormally and does not drop within 10 minutes, the
unit will enter standby mode. The dehumidier will not
operate until the circuit has cooled.