INSTALLATION REQUIREMENTS
Fig. 5
Fig. 6
installation area for the connection
ELECTRICAL
A properly-grounded horizontally- mounted electrical
receptacle should be installed no higher than 3″ (7.6 cm)
above the floor, no less than 2″ (5 cm) and no more than 8″
(20.3 cm) from the left side (facing product).
Check all local code requirements.
GAS
An agency-approved, properly-sized manual shut-off valve
should be installed no higher than 3″ (7.6 cm) above the
floor and no less than 2″ (5 cm) and no more than 8″ (20.3
cm) from the right side (facing product).
To connect gas between shut-off valve and regulator, use
agency-approved, properly sized flexible or rigid pipe.
Check all local code requirements.