Loading ...
Loading ...
Loading ...
![](https://files.manualsfile.com/38481769-pro305gasxv/bge.png)
SPECIFICATIONS
Burner
Injector
Gas Pressure Max Rate Min Rate
By–pass
diam.[mm] Type [iwc] [Btu/hr] [W] [Btu/hr] [W] diam.[mm]
Auxiliary
0.90
0.54
NG
LP
(Propane)
4″
10″
3,500
3,300
1,025
967
900
900
264
264
Regulated
0.29
Semi-rapid
1.18
0.70
NG
LP
(Propane)
4″
10″
5,900
5,500
1,729
1,611
1,500
1,500
439
439
Regulated
0.36
Rapid
1.55
0.92
NG
LP
(Propane)
4″
10″
10,400
9,500
3,047
2,783
2,500
2,500
732
732
Regulated
0.47
Dual
burner
0.80+2.10
0.50+1.20
NG
LP
(Propane)
4″
10″
19,000
19,000
5,567
5,567
1,300
1,300
381
381
Regulated
0.34/0.65
Oven 30″
1.85
1.10
NG
LP
(Propane)
4″
10″
14,000
14,500
4,102
4,248
3,500
3,500
1,025
1,025
Regulated
0.60
Broiler 30″
1.40
0.98
NG
LP
(Propane)
4″
10″
9,000
10,500
2,637
3,076
only max
only max
only max
only max
No by-
pass
No by-
pass
See use and care manual for the layout of the surface burners of your range
14
Loading ...
Loading ...
Loading ...