Bosch GPB18V-2CN 18V Compact Jobsite Radio with Bluetooth 5.0 , Black

User Manual - Page 9

For GPB18V-2CN.

PDF File Manual, 56 pages, Read Online | Download pdf file

GPB18V-2CN photo
Loading ...
Loading ...
Loading ...
Assembly and Set Up
Clock Battery
Risk of explosion if
the battery is
replaced by an incorrect type. Use only
CR2032 batteries.
Chemical Burn Haz -
ard. Do not ingest
battery. Keep new and used batteri es
away from children.
This product contains a lithium
button/coin cell battery. If a new or
used lithium button/coin cell battery is
swallowed or enters the body, it can
cause severe internal burns and can
lead to death in as little as 2 hours.
Always completely secure the battery
compartment. If the battery
compartment does not close securely,
stop using the product, remove the
batteries, and keep it away from
children.
If you think batteries might have been
swallowed or placed inside any part of
the body, seek immediate medical
attention.
To install clock battery:
1. Release the locking latch 14 and
open battery bay door 13.
2. Remove clock battery cover 18 by
inserting a coin into the slot on the
cover and rotating the cover
counterclockwise (Fig. 2).
3. If opening the battery compartment
for the first time, remove the clear
plastic strip 27. If replacing battery,
remove old battery and dispose of
properly (Fig. 2).
4. Insert (new) CR2032 battery 26.
Make sure that the positive (+) side
of the battery is facing up.
5. Replace clock battery cover by
inserting a coin into the slot on the
cover and rotating the cover
clockwise until the cover locks into
place.
6. To close the battery bay door, bring it
up against the seal on the housing
and lock it by placing the latch's
catch in the mating slot on the
housing and pressing the latch's lever
section.
-9-
Functional Description and Specifications
Electrical Ratings Voltage rating 18 V
Radio
AM 530–1710 kHz
FM FM 87.5–107.9 MHz
Memory
AM 4 presets
FM 8 presets
Ingress Protection IP Rating
IP54 only when battery bay
door is installed and closed.
Allowed ambient
temperature
during charging
during operation and storage
32...95 °F (0...+35 °C)
–4...104 °F (–20...+40 °C)
Battery Packs/Chargers
Please refer to the battery/charger list, included with your unit.
18
26
27
Fig. 2
Loading ...
Loading ...
Loading ...