9
ENG
INSTALLATION
Cut out the work surface according to the sizes shown in the drawing.
For the purpose of installation and use, a minimum of 5 cm space shall be preserved around the hole.
Be sure the thickness of the work surface is at least 30 mm. Please select
heat-resistant work surface material to avoid larger deformation caused by the heat radiation from the hotplate.
As shown below:
Selection of installation equipment
L (mm) W (mm) H (mm) D (mm) A (mm) B (mm) X (mm)
290 520 50 45 270 495 50 min
Note: The safety distance between the hotplate and the cupboard above the hotplate should be at least
760 mm.
Under any circumstances, make sure the Ceramic cooker hob is well ventilated and the air inlet and outlet are not
blocked. Ensure the ceramic cooker hob is in good work state. As shown below.
A (mm) B (mm) C (mm) D E
650 50 mini 20 mini Air intake Air exit 5mm
SEAL