The appliances are prepared for connection to the voltage shown on the data plate.
Before connecting the appliance to the mains check that:
the electromagnetic switch or the socket are able to support the appliance’s
load (see data plate);
the power supply system must have an efcient earth.
The appliance is supplied with a cable but without a plug: the connection must be made
taking into account that the green-yellow cable is the earth conductor
and it must
never be interrupted.
For direct connection to the mains, it is necessary that:
the relief valve and domestic system can support the equipment’s load (see data
plate)
the power supply system must have an efcient earth
the socket or omnipolar switch, with a minimum 3 mm contact opening, must be easily
reached once the appliance has been installed a mains shut-off must be incorporated
in accordance with installation rules.
The green-yellow earth cable must never be interrupted even by the switch. The
power cable must be routed in such a way that it does not come into contact with
surfaces that have a temperature greater than 50°C above room temperature. If
cable replacement is necessary contact the after-sales service.
* HP965B, HP1265B, HP90B, HP120B
INSTALLATION
Electric connection
Power (230V) (240V)
Hotplate (Ø 115) 550 W 600 W
Hotplate (Ø 115) 920W 1000 W
Hotplate (Ø 115) 1380 W 1500 W
Barbeque 1900 W 2070 W
Barbeque* 2650 W 2880 W
(UNI CIG 7129/7131)
The appliances must be attached to the gas pipeline with rigid or exible metal pipes
(maximum length 2 metres) suitable for gas appliances. The connection pipes and their
maximum length must comply with the applicable standards, replaced before the expiry
date (if indicated on the pipe) and connected to the appliance by a coupling:
A) Directly on the ISO R228 tting (seal with ISO R228 seal), if the pipe path allows it,
see pic. 3
B.1) In the event that the connection should be directed (right-left-low), it is necessary
to interpose the tting (pic. 4a - g. 4b) supplied
B.2) For the seal between the pipe and the ramp use the gasket (ISO R228) pic. 4a
B.3) For sealing on the thread (ISO R7) conical ttings with the thread seal must be
used (pic. 4b)
B.4) To improve the seal a mastic suitable for GAS can be used.
When the gas is drawn from a cylinder, the appliance, supplied with a pressure regulator
compliant with standard UNI-CIG 7432, must be connected: with exible stainless steel
pipes along the wall, according to standard UNI-CIG 9891, with 2 metres maximum
extension and sealing gasket according to standard UNI 9264..
The gas taps tted in your kitchen must work with liquid gas of controlled quality, supplied
at the proper nominal pressure. This pressure must be guaranteed by a special certied
pressure regulator. The use of gas coming from uncertied sources and/or the improper
use of the GPL cylinder as well as the relative regulator, can invalidate the product’s
guarantee. It is especially necessary to avoid all the situations that could pollute the gas
with residues and impurities that, when introduced into the gas circuit, can irreparably
damage the control components such as taps and thermostats. It is recommended to:
use only GPL cylinders coming from ofcial retailers and authorised by the various
manufacturers;
use the cylinders until empty without inclining or overturning them;
carry out regular cleaning of the lter at the pressure regulator inlet;
When the connection is made, it is recommended to check the connections’ seal
with special foams (NO FLAMES).
Periodically check the gas connection pipe’s good condition and replace it when there are
signs of anomalies.
Gas connection