2
For 1000V Protection: Max.
1000V AC/DC
But 10V/50V only
250V Max. Band
width: 40 ~10K Hz
DC mA 0-0.05-2.5-25-25
0 mA, 10A
3% FSD.
4% FSD.
For 10A
Drop Voltage: 250
mV Overload
protected by Fuses
0.5A/250V & 10A /
250V at 10A range,
and Oxide
Varactor.<250V
AC/ DC(5s). Max.
test time 15sec. for
10A.
X 1: 0.2 ~ 2K
Midscale at 20Ω
X 10: 2 ~ 20KΩ
Midscale at
200Ω
X 100: 20 ~
200KΩ
Midscale at
2000Ω
X1K: 200~ 2MΩ
Midscale at
0KΩ
X10K: 2K
~20MΩ
Midscale at
200KΩ
4% of
ARC of
Scale
Length
Overload protected
by the Oxide
Varactor & Fuse
<250V AC/DC (5s).
Capacitance
(uF)
C: 2,000uF Max.
.
Approx.
Value
Use the R x 1K
range
BATT Check 0 ~ 1.5V: GOOD
- ? – BAD
0 ~ 9V: GOOD
- ? – BAD
5% of
ARC of
Scale
Length
Load Current:
270mA for 1.5V
25mA for 9V
Overload protected
by Fuse & Oxide
Varactor .<250V
AC/DC(5s).
Transistor
Check
hFE: 0-1000 via
special hFE
socket
Approx.
Value
At Ω X 10 Range
LED, Diode via special hFE Approx. At Ω X 10 Range