AJ600
Injector Cleaner & Tester
ANCEL
VII. Troubleshooting & Precautions
7.1
Troubleshooting
1) The unit does not correspond when it is switched on.
2) Check the fuse at lower right side of the unit and replace it if it is damaged or broken.
3) There is leakage in the fuel separator coupler.
4) Fuel leaked at coupling element of fuel separator. Please check whether the O ring installed matches and if it deformed or
damaged. If it does not match or is damaged, please change it. The two black adjusting screws should not be too tight, which
may also cause the coupling element of fuel separator to leak fuel.
5) Draining the test liquid in glass tube thoroughly requires pressing the DRAIN icon more times.
6) The solenoid valves will stop automatically after 15 seconds and it is necessary to drain more times if there is more liquid.
7.2
Precautions
1) In order to avoid electric shock, keep away from the damp part of a working unit and avoid exposing it to the rain.
2) To ensure operation safety, please make sure that equipment has been connected to ground well.
3) Do not operate equipment with a damaged cord or if the equipment has been dropped or damaged until it has been examined
by qualified service personnel.
4) Equipment use is strictly prohibited fireworks, and posted No smoking and Flammable hazard warning signs.
5) Please operate the unit according to the operation procedures in the manual. Only use the accessories recommended by the
manufacturer.
6) ALWAYS WEAR SAFETY GOGGLES. Common used glasses are NOT safety glasses.