8
FRONT PANEL FUNCTIONS
ENGLISH
[10] PHANTOM POWER +48 V CH1/8 AND 9 TO 16 SWITCHES
Dedicated to the Mic input this switches allows the +48 V Phantom Power to the Mic input: 1-8 and
9-16 to be enabled. Enabling of the Phantom power is necessary only in the presence of Condenser
and Electret Microphones or in case of D.I. boxes usage.
[11] CHANNEL 1 TO 16 GAIN
MIC input (XLR). These controls permit the gain for MIC input to be set with a range from 0 dB to -50 dB. If the LINE INPUTS (TRS jack) are in in use the
gain range permitted is from +20 dB to -30 dB. All the F 24XR’s MIC-LINE inputs are supplied with an 80 Hz High-pass filter. Enable the 80 Hz High-Pass
filter when using microphone for voice to reduce low frequency pop, bump and rumble noises.
2 2 2 2 2 2 2 2
[12] CHANNEL 17/18 AND 19/20 GAIN
MIC input (XLR). These controls permit to the gain for MIC input to be set with a range from 0 dB to
-50 dB. Corresponding LINE INPUT (TRS jack) have a fixed input level gain.
[13] CHANNEL 21/22 AND 23/24 GAIN
STEREO LINE INPUT (TRS jack). The controls allow a gain range control from +20 dB to -30 dB.
2 2
[14] IN USB - IN 23/24 BUTTON
USB IN determines that the stereo audio channels played from an external computer connected to the
USB port are routed to the stereo channel 23/24. When the button is in upper position (not pressed)
the audio coming from LINE INPUT 23/24 is routed to MAIN MIX; If the USB IN button is pressed the
audio coming from an external computer is routed to the stereo channel 23/24; in this instance the
USB audio substitutes the analog audio input and takes advantage of all the features provided by the
stereo channel such as EQs, AUX send, BAL and fader control.
[15] LEVEL METER
This 12 LED elements level meter allows you to control the Main Mix output level. Keep the output level
below the “CLIP” indication to avoid overloaded signals that can cause distortion.
[16] COMPRESSORS
Input channels 1 to 6 are provided with intuitive and powerful single control dynamic compressors. With thresholds and ratio parameters properly
designed the F 24XR’s compressors allow even the most dynamically demanding signals to be controlled.
[17] EQ (MONO CHANNELS)
All the F 24XR’s mono channels are provided with a sophisticated and precise 3-band EQ. Low frequency control sets in at 100 Hz with a gain of +/-15 dB
and shelving curve. Hi frequency control sets in at 10 kHz with a gain of +/-15 dB and shelving curve. Mid frequency control provide a frequency selection
between 100 Hz to 8 kHz with a gain of +/-15 dB and bell curve.