Performance Data Sheet Model: XWF or XWFE
Ŷ6\VWHPFHUWLILHGE\,$30257DJDLQVW16)$16,6WDQGDUGV3IRUWKHUHGXFWLRQRIFODLPVVSHFLILHGRQWKH
performance data sheet and at iapmort.org.
Ŷ$FWXDOSHUIRUPDQFHPD\YDU\ZLWKORFDOZDWHUFRQGLWLRQV
It is essential that the manufacturer’s recommended
installation, maintenance and filter replacement
requirements be carried out for the product to
perform as advertised. See Installation Manual for
Warranty information.
Application Guidelines/Water Supply Parameters
Service Flow 0.5 gpm (1.89 lpm)
Water Supply Potable Water
Water Pressure 25-120 psi (172-827 kPa)
Water Temperature 33°F-100°F (0.6°C-38°C)
Capacity 170 gallons (643.5 liters)
Substance Tested for Reduction
Influent challenge
concentration
(mg/L)
Maximum permissible
product water
concentration (mg/L)
Avg %
Reduction
Chlorine Taste and Odor 2.0 mg/L +/- 10% N/A 96.9
Chloramine Taste and Odor 3.0 mg/L +/- 10% 0.5 96.9
Particulate, Class I At least 10,000/mL N/A 91.4
Cysts 50,000/L N/A >99.99
Lead 0.15 0.01 98.85
Mercury 0.006 0.002 96.3
Asbestos 107 to 108 fibers/ L N/A >99
Toxaphene 0.015 +/- 10% 0.003 86.95
VOC (Chloroform surrogate chemical) 0.300 0.015 99.7
Alachlor 0.050 0.001 > 98
Atrazine 0.100 0.003 > 97
Benzene 0.081 0.001 > 99
Carbofuran 0.190 0.001 > 99
carbon tetrachloride 0.078 0.0018 98
chlorobenzene 0.077 0.001 > 99
chloropicrin 0.015 0.0002 99
2,4-D 0.110 0.0017 98
dibromochloropropane (DBCP) 0.052 0.00002 > 99
o-Dichlorobenzene 0.08 0.001 > 99
p-Dichlorobenzene 0.040 0.001 > 98
1,2-dichloroethane 0.088 0.0048 95
1,1-dichloroethylene 0.083 0.001 > 99
cis-1,2-dichloroethylene 0.170 0.0005 > 99
trans-1,2-dichloroethylene 0.086 0.001 > 99
1,2-dichloropropane 0.080 0.001 > 99
cis-1,3-dichloropropylene 0.079 0.001 > 99
dinoseb 0.170 0.0002 99
Endrin 0.053 0.00059 99
Ethylbenzene 0.088 0.001 > 99
ethylene dibromide (EDB) 0.044 0.00002 > 99
bromochloroacetonitrile 0.022 0.0005 98
dibromoacetonitrile 0.024 0.0006 98
dichloroacetonitrile 0.0096 0.0002 98
trichloroacetonitrile 0.015 0.0003 98
1,1-dichloro-2-propanone 0.0072 0.0001 99
1,1,1-trichloro-2-propanone 0.0082 0.0003 96
heptachlor (H-34, Heptox) 0.025 0.00001 >99
heptachlor epoxide 0.0107 0.0002 98
hexachlorobutadiene 0.044 0.001 > 98
hexachlorocyclopentadiene 0.060 0.000002 > 99
Lindane 0.055 0.00001 > 99
methoxychlor 0.050 0.0001 > 99
pentachlorophenol 0.096 0.001 > 99
simazine 0.120 0.004 > 97
Styrene 0.150 0.0005 > 99
1,1,2,2-tetrachloroethane 0.081 0.001 > 99
Tetrachloroethylene 0.081 0.001 > 99
Toluene 0.078 0.001 > 99
2,4,5-TP (silvex) 0.270 0.0016 99
tribromoacetic acid 0.042 0.001 > 98
1,2,4-Trichlorobenzene 0.160 0.0005 > 99
1,1,1-trichloroethane 0.084 0.0046 95
1,1,2-trichloroethane 0.150 0.0005 > 99
trichloroethylene 0.180 0.0010 > 99
bromoform 0.300 0.015 95
bromodichloromethane 0.300 0.015 95
chlorodibromomethane 0.300 0.015 95
xylenes 0.070 0.001 >99
Meprobamate 400 +/- 20% 60 95.5
Atenolol 200 +/- 20% 30 95.9
Carbamazepine 1400 +/- 20% 200 98.6
DEET 1400 +/- 20% 200 98.6
Metolachlor 1400 +/- 20% 200 98.7
Trimethoprim 140 +/- 20% 20 96.1
Linuron 140 +/- 20% 20 96.6
TCEP 5000 +/- 20% 700 98.1
TCPP 5000 +/- 20% 700 98.1
Phenytoin 200 +/- 20% 30 96
Ibuprofen 400 +/- 20% 60 95.9
Naproxen 140 +/- 20% 20 96.5
Estrone 140 +/- 20% 20 97.1
Bisphenol A 2000 +/- 20% 300 99.1
Nonyl phenol 1400 +/- 20% 200 97.3
PFOA/PFOS 1.5 mg/L +/- 10% 0.07 99.25
NOTE: While the testing was performed under
standard laboratory conditions, actual performance
may vary.
Replacement Cartridge: XWF or XWFE. For
estimated costs of replacement elements please visit
our website at gewaterfilters.com.
WARNING
To reduce the risk
associated with ingestion of
contaminants:
Do not use with water that is microbiologically
unsafe or of unknown quality without adequate
disinfection before and after the system.
Systems certified for cyst reduction may be used on
disinfected water that may contain filterable cysts.
AVERTISSEMENT
Pour réduire le risque
associé à l'ingestion de
contaminants:
N'utilisez pas l'appareil avec de l'eau d'une
qualité incertaine ou non potable sur le plan
microbiologique sans une désinfection en
amont et en aval du système. Les systèmes
homologués relativement à la réduction d'oocystes
peuvent être utilisés avec de l'eau désinfectée
pouvant contenir des oocystes filtrables.
ADVERTENCIA
A fin de reducir el riesgo
asociado con la ingestión
de contaminantes:
No se deben usar con agua que no sea
microbiogicamente segura o de calidad
desconocida sin una desinfección adecuada,
antes o después, del sistema. Los sistemas
certificados para la reducción de quistes se podrían
usar en aguas desinfectadas que puedan contener
quistes filtrables.
PERFORMANCE DATA
Loading ...
Loading ...
Loading ...