Ancona AN-1323 36 in. Insert B336D 420 CFM Ducted Range Hood

User Manual - Page 15

For AN-1323.

PDF File Manual, 20 pages, Read Online | Download pdf file

AN-1323 photo
Loading ...
Loading ...
Loading ...
— 15 —
Troubleshooting
Problem Possible Cause
If the range hood or halogen light
does not operate after installation:
Check if the range hood has been plugged in, make sure that
all power has been turned back ON, fused not blown and all
electrical wiring is properly connected.
The range hood vibrates when the
blower is on:
The range hood might not have been secured properly on to the
ceiling or wall.
The blower or fan seems weak: Checkthattheductsizedusedisatleast6in.(15.3cm)or
3-1/4 × 10 in. (8.3 × 25.4 cm). Range hood WILL NOT function
efcientlywithinsufcientductsize.Forexample:7in.(17.7cm)
duct over 6 in. (15.3 cm) hole and loosely secured.
Checkifductiscloggedorifdamperunit(half-circularange)is
not installed correctly or opening properly. A tight mesh on a side
wallcapunitmightalsocauserestrictiontotheairow.
The lights work but the fan is not
spinning at all, is stuck or is rattling:
The fan might be jammed or scraping the bottom due to
shipping damage. Please contact us immediately.
The hood is not venting out
properly:
Make sure the distance between the stove top and the bottom of
the hood is within 24 in. and 30 in. (61 and 76.2 cm) distance.
Reduce the number of elbows and length of duct work. Check if
all joints are properly connected, sealed, and taped.
Loading ...
Loading ...