Circuit Diagram
When the door is closed, normal close contact
When the door is open, contact is disconnected
Notes for installation:
1. Sensor leads must be kept separately from main voltage wires in order to avoid high frequency
noise induced. Separate the power supply of the loads from the power supply of the controller.
2. When installing, the sensor must be placed with the head upward and the wire downward.
3. The temperature controller must not be installed in an area where water drips.