PLEASE READ AND SAVE THESE INSTRUCTIONS
MISTING FAN
OWNER'S MANUAL
MODEL: FM-48 (115V/60HZ)
XPOWER MANUFACTURE, INC.
240 Clary Avenue
San Gabriel, CA 91776, USA
Tel: 626-285-3301 Fax: 626-285-3302
www.xpower.com

TABLE OF CONTENTS
Introducon..................................................................................................................................... 3
Operaon Instruscons .............................................................................................................. 4, 5
Safety Instrucons .......................................................................................................................6, 7
User Servicing Instrucons ............................................................................................................ 8
Troubleshoong ............................................................................................................................10
Specificaons...................................................................................................................................9
Parts List .......................................................................................................................................11
XPOWER Warranty / Service .........................................................................................................14
Warranty Registraon Form ....................................................................................................15, 16
More XPOWER Products..........................................................................................................12, 13

- 3 -
Intr
XPOWER Mis Fans are ETL & C-ETL cer professional level mul func blowers /
fans with the most efficient engineering design.
Feartures:
• Low power draw with a high velocity air flow up to 600 CFM
• Super quiet and super light weight
• Easy and quick to disassemble for thorough cleaning and service
• Convenient cord and water hose wrap design
• Power cord length up to 7' / Water hose length up to 10'
• 3 Speed switch
• Safety screens on open vents
• In-line GFCI cord for safe outdoor use
• Durable and rugged housing with 1 year warranty
Fused end plug•

- 4 -
Opera s
XPOWER Mis ng Fans are intended to deliver a fine mist to cool and refresh outdoor areas
up to 30 °F. Durable and easy to operate with an eff ve balance of airflow and mis ng, the
units are suitable for a variety of applica ons.
1. XPOWER Mis ng Fans are shipped ready-to-use. Prior to plugging the unit into the power
source, inspect completely for any shipping damage.
2. Screw on the mis ng nozzles if they were removed during storage.
3. Unwrap the electrical cord and water hose. Connect the hose adapter to a standard garden
faucet if mis ng fun on is needed.
4. Plug the electrical cord into a 3-prong outlet.
5. Carefully place the unit on a stable, flat dry surface.
6. Turn the switch to desired speed and rotate the
machine to desired posi on, while making sure
unit operates normally. Turn on the faucet and
the switch on the hose adapter.
(Con
nued at Page 5)
Adjust the misng angle

- 5 -
7. All units in opera on must be supervised at all mes.
8.
When finished, turn off the faucet and the switch on the hose adapter.
turn off
Wrap the water hose first around
the handle on the Mis
ng Fan and then the electrical cord.
Then

- 6 -
Safety Ins
2. To prevent electric shock, do not operate the unit in standing water. Never plug in or unplug
the unit with wet hands or while standing in water.
3. To avoid risk of injury, do not redirect air flow at face or body.
4. WARNING - To reduce the risk of fire or electric shock, do not use this fan with any solid-state
speed control device.
5.
CAUTION: To reduce the risk of the electric shock, connect only to an outlet provided with a ground
lease contact a qualified electrician for verifica on and / or
installa on of a GFCI receptacle if necessary.
7. Do not operate the Mis
ng Fan with a damaged cord or plug. Discard the unit or return it to
an authorized service facility for examina
on and / or repair.
8. Unplug the Mis
ng Fan from the power supply before servicing or cleaning.
9. Do not run the power cord under carpeng. Do not cover the cord with throw rugs, runners, or
similar coverings. Do not route cord under furniture or appliances. Arrange cord away from
traffic area and where it will not be tripped over.
10. Do not allow children to play with or around the Mis
ng Fan at any .
siM eht yrrac ro evom ton oD .11
ng Fan while the unit is opera ng.
12. Always place the Mis
ng Fan on a smooth and level surface for safe opera on.
13. Any misuse or abuse of this product will void its warranty.
servicing.
1. This fan is an outdoor product and is NOT intended for indoor use. Do not leave the fan
6

- 7 -
Safety Ins
The power cord is equipped with a three-prong, grounded fused end plug with a in-line GFCI (Ground
Fault Circuit Interrupter). It must be inserted into a grounded receptacle. Under no circumstances
must the grounding prong be cut off the plug.
WARNING: Do not use a three-prong to two-prong adapter.
1. Plug into power outlet,indicator is “ON”.
2.Press TEST buon,indicator is “OFF”.
3.Press RETEST buon again when using the Misng Fan.
DO NOT USE IF TEST FAILS.
WARNING
RISK OF ELECTRIC SHOCK. Test GFCI before each use.
14.This product employs overload protecon (fuse). A blown fuse indicates an overload or short-circuit
situaon.If the fuse blows,unplug the product from the outlet.Replace the fuse as per the user
servicing instrucons (follow product marking for proper fuse rang) and check the product. If the
replacement fuse blows,a short-circuit may be present and the product should be discarded or
returned to an authorized service facility for examinaon and /or repair.
15. Turn off water at the source before changing the nozzle or aer each use.
chemical-laden or where gasoline,paint or flammable liquids are used or stored.
other animals are confined.
.
indicator
RETEST button
TEST button

- 8 -
User Servicing Instrucons
1. To keep the Misng Fan clean, use a damp cloth to wipe the surface of the housing.
2. To clean the misng nozzles, disassemble the nozzles (See pictures below) and soak the parts
with soapy water or mild (or alkaline) detergent for several hours. Do not use vinegar or other
acidic detergent. When finished, dry the surfaces completely and reassemble the parts.
3. When not in use, screw off the misng nozzles, unplug and store the Misng Fan and nozzles
in a dry indoor place out of reach of children. The nozzles must be dried completely before
stored.
4. Always disconnect the Misng Fan from its power source before maintenance or cleaning.
Replace the fuse:
1. Grasp plug and remove from the receptacle or other outlet device. Do not unplug by pulling on cord.
2. Slide open the fuse cover on top of aachment plug towards blades.
3. Remove the fuse carefully.
4. Risk of fire. Replace fuse only with 5A,125 Volt fuse.
5. Slide closed the fuse cover on top of the aachment plug.
6. Risk of fire. Do not replace aachment plug contained a safe device(fuse) that should not be removed.
Discard product if the aachment plug is damaged.
fuse
fuse cover

- 9 -
Specifica
Model Number FM-48 Cer ca ETL / C-ETL
Volt / Frequency 115V / 60Hz RPM 900 / 1150 / 1400
Power 138 Wa s Speeds 3 Speed
Amp 1.2 Amps Unit / Box Weight 10.1 lbs. / 11.7 lbs.
Rated Airflow (On High) 600 CFM
Unit / Box Dimension
(L x Wx H)
13.3" x 12.3" x 15.2" /
13.6"x 12.7" x 14.6"
Power Cord (Length )
7' Housing PP
Water Hose Length 10'

- 10 -
Troubleshoong
PROBLEM POSSIBLE CAUSE SOLUTION
Misng Fan not
running
No power input / Switch not turned
on
Check outlet / switch to another outlet, make sure
unit is plugged in and switch is turned on.
Intake or exhaust blocked Turn unit off to cool down, then remove blockage
Fan jammed Remove material jamming the fan
Wiring failure / Motor Failure contact XPOWER Customer Service
Misng Fan vibrates
/ makes noise
Fan jammed / broken
Remove material jamming the fan or contact
XPOWER Customer Service
Nozzles not misng
No water supply
Check water supply / Make sure the water hose is
connected and switch is turned on.
Nozzle jammed
Clean the nozzle according maintenance
instrucons

- 11 -
Parts List
Item No. Parts Name
1 Le housing
2 Air outlet grid cover
3 Panel
4 Switch assembly
5 Fan
6 Sha sleeving
7-1/7-2
Plug / GFCI
8 Water hose
9 Rack knob
10
Misng nozzles
11
Rack
12 Right housing
13 Capacitor
14 Grid Cover
15
7-1
7-2
15
Motor

- 12 -
Jan/San - Restoraon & Migaon Equipment:
Centrifugual Fans
Low Profile Air Movers
Scented Air Mover Fans
Airrow Pro Blower
Confined Space Fans
Axial Fans
High Temp Axial Fans
Air Scrubbers
Dehumidifiers
Misng Fans
More XPOWER Products Available

- 13 -
Inflatable Adversing Equipment:
High Stac Blowers
Centrifugal Blowers
Vercal Adversement Blowers
Air Pumps
Professional & Retail Pet Grooming Equipment:
Professional Pet Grooming Dryers
DIY Pet Grooming Dryers
Air Care Equipment
Learn more at www.xpower.com or call 1-855-855-8868

- 14 -
XPOWER Limited Warranty (USA)
Service
XPOWER's Limited Warranty covers the unit (excludes power cord, motor brushes, and any other consumable parts) from defects
in material and crasmanship. The Warranty covers normal use for a term of one year from the original date of purchase including
parts, labor, and one way shipping. Non-conguous states must pay for roundtrip freight. Warranty honored with original proof of
purchase only.
Important!
This Warranty does not cover or apply to defects directly or indirectly due to misuse, abuse, disassembly, alteraon, corrosive
chemicals, improper voltage, fire, flood, negligence, accident, improperly or incorrectly performed maintenance or repair, or
failure to perform necessary maintenance or repair, or if the use of this product is not in compliance with the instrucons and
specificaons for its use.
For Warranty service and parts replacement (US customer only), you must:
A. Call 1-855-855-8868 for a RMA (Return-Merchandise-Authorizaon) number.
B. Have original proof of purchase provided.
C. Use the original undamaged packaging or an industrial cerfied packaging method.
End user will be responsible for shipping the unit (with RMA Number showing on the shipping label) to XPOWER Customer
Service Department. XPOWER will inspect, assess and advise the repairs needed and applicable cost, if any.
For users outside US, please contact an XPOWER Distributor in your country or region for warranty service and parts replacement.

For your product warranty, please complete and mail / fax this form to XPOWER MANUFACTURE, INC.
Address: 240 Clary Ave., San Gabriel, CA 91776. Tel: 626-285-3301 Fax: 626-285-3302
Warranty Registration
Company Name / Contact Person / Title
State / Province
Zip Country
(for US customer only)
(For your convenience, register your product online at xpower.com)

TO:
XPOWER MANUFACTURE, INC.
240 Clary Avenue
San Gabriel, CA 91776, USA
Tel: 626-285-3301, Fax: 626-285-3302
From: