2. Replace safety valve
1. Drain tank, tilt tank to drain and drain tank more frequently
2. Move compressor to area with less humidity, or use water separator.
TROUBLESHOOTING
PROBLEM POSSIBLE CAUSE(S) CORRECTIVE ACTION
Compressor will not run
Thermal Overload Protector cuts out repeatedly
Excessive knocking or rattling
1. No power, or switch in Off position.
2. Blown Fuse.
3. Motor over heat.
4. Faulty pressure switch (if hooked up to a pressure switch).
1. Lack of proper ventilation/ambient temperature too high.
2. Compressor valves failed.
1. Loose mounting bolts
2. Worn bearing on eccentric or motor shaft
3. Cylinder or piston ring is worn
1. Make sure compressor switch is ON
2. Disconnect compressor from power and replace fuse. (Refer to Specifications
section for correct fuse amperage.)
3. Let compressor cool off for about 30 minutes for thermal overload switch reset.
4. Replace pressure switch
1. Move compressor to well ventilated area, or area with lower ambient temperature
2. Replace compressor
1. Tighten bolts
2. Replace compressor