Waldorf FNB8130GE Bold 600mm Gas Fryer

Installation Operation Manual - Page 13

For FNB8130GE.

PDF File Manual, 40 pages, Read Online | Download pdf file

FNB8130GE photo
Loading ...
Loading ...
Loading ...
11
2. A suitable joining compound which resists the breakdown action of LPG must be used on every gas
line connection, unless compression fittings are used.
Connection to appliance is
3
/
4
BSP male.
NOTE: A Manual Isolation Valve must be fitted to individual appliance supply line.
3. Correctly locate appliance into its final operating position and using a spirit level, adjust legs so that
unit is level and at correct height.
4. Connect gas supply to appliance.
5. Check all gas connections for leakages using soapy water or other gas detecting equipment.
6. Check gas supply pressure is as shown in Specifications section, Gas Supply Requirements table.
NOTE: Measure gas supply pressure at Upper Test Point (Supply Pressure) on the gas control
valve.
7. Light Pilot Burners. Refer to Operation section, Lighting Pilot Burners.
8. Check pilot flame size. Re-adjust if required, using pilot adjusting screw (See Fig 3 below), and as
shown in Gas Conversion and Specifications section, Pilot Burner Flame Adjustment.
9. Light the Main Burners. Refer to Operation section, Lighting Main Burners.
10. Verify Supply Pressure is still correct.
11. Check Main Burner operating pressure (Adjust, using
Operating Pressure Adjusting Screw on Gas
Control Valve, see Fig 3), and as shown in Gas
Conversion and Specifications section, Main
Burner Operating Pressure Adjustment.
NOTE: Insufficient gas supply line capacity, indicated by
operating pressure drop during maximum gas
supply demand, is NOT ACCEPTABLE and may
invalidate the manufacturers warranty for this
appliance.
IMPORTANT:
DO NOT USE A NAKED FLAME TO CHECK FOR GAS LEAKAGES.
Supply Pressure
Test Point
Operating Pressure
Test Point
Pilot Adjusting
Screw
Operating Pressure
Adjusting Screw
Fig 3
Loading ...
Loading ...
Loading ...