76
Click
Clear
to delete all drawn detection lines.
Step 5 Select
Enable
, and then set the interval and sensitivity.
Interval: The time that calling behavior lasts. When the Camera detects the calling time
beyond the configured value, an alarm is triggered.
Sensitivity: The larger the value is, the more sensitive the call detection is. However,
setting the value too large might cause false alarm.
Step 6 Configure arming periods and alarm linkage action. For details, see "5.1.1 Alarm Linkage"
and "5.1.2 Setting Period".
Step 7 Click
Save
.
Result
According to the configured rules, when call action is detected in the detection area, an alarm is
triggered, and the Camera performs linkage actions.
Click the
Alarm
tab on the main page, and then select
IVS
. When an alarm is trigged, you can view
the details on the
Alarm
page.
5.5.5 Configuring Global Setup
Configure global rules for smoking detection. You can draw the detection area and exclusion areas.
When the configured rules are triggered in the detection areas (out of the exclusion areas), an alarm
will be triggered.
Procedure
Step 1 Select
Setting
>
Smart Thermal
>
Smoking Detection
>
Global Setup
.
Step 2 Select the preset.
The preset with the smart plan enabled is green.
Figure 5-43 Global setup
Step 3 Add detected area and excluded area.
1) Click
Add Detect Region
to draw a detected area on the image. Right-click to end
drawing.
Loading ...
Loading ...
Loading ...