AIDA Imaging PTZ-NDI-X12 Full HD NDI HX Broadcast PTZ Camera with 12x Optical Zoom

User Manual - Page 28

For PTZ-NDI-X12.

PDF File Manual, 38 pages, Read Online | Download pdf file

PTZ-NDI-X12 photo
Loading ...
Loading ...
Loading ...
VISCA Protocol
(CONTD)
21
CAM_DZoom
Stop 81 01 04 06 00 FF Enable in separate mode
Tele(Variable) 81 01 04 06 2p FF Enable in separate mode
Wide(Variable) 81 01 04 06 3p FF
Enable in separate mode
Direct 81 01 04 46 0p 0q 0r 0s FF
Enable in separate mode
CAM_Focus
Stop 8x 01 04 08 00 FF
Far(Standard) 8x 01 04 08 02 FF
Near(Standard)
8x 01 04 08 03 FF
Far(Variable) 81 01 04 08 2p FF
p=0 (Low) to 7 (High)
Near (Variable)
81 01 04 08 3p FF
p=0 (Low) to 7 (High)
Direct
8x 01 04 48 0p 0q 0r 0s FF
pqrs: Focus Position
Auto Focus
81 01 04 38 02 FF
Manual Focus 81 01 04 38 03 FF
One Push AF 8x 01 04 18 01 FF
CAM_ZoomFocus
Direct 8x 01 04 47 0p 0q 0r 0s 0t 0u 0v 0w FF
pqrs: Zoom Position (0(wide)~0x4000(tele)) tuvw:
Focus Position
CAM_WB
Auto
8x 01 04 35 00 FF
Indoor 8x 01 04 35 01 FF
Outdoor
8x 01 04 35 02 FF
One Push
8x 01 04 35 03 FF
ATW
8x 01 04 35 04 FF
Manual
8x 01 04 35 05FF
Sodium lamp
8x 01 04 35 08 FF
Flourescent
8x 01 04 35 09 FF
One Push Trigger
8x 01 04 10 05 FF
CAM_RGain
Reset
8x 01 04 03 00 FF
Manual Control of RGain
Up
8x 01 04 03 02 FF
Down
8x 01 04 03 03 FF
Direct
8x 01 04 43 00 00 0p 0q FF pq: RGain (0~0xFF)
CAM_BGain
Reset
8x 01 04 04 00 FF
Manual Control of BGain
Up
8x 01 04 04 02 FF
Down
8x 01 04 04 03 FF
Direct
8x 01 04 44 00 00 0p 0q FF
pq: BGain (0-0xFF)
Loading ...
Loading ...
Loading ...