Bosch VGD011BR0M/01 90 cm built-in gas oven

User Manual - Page 44

For VGD011BR0M/01.

PDF File Manual, 48 pages, Read Online | Download pdf file

VGD011BR0M/01 photo
Loading ...
Loading ...
Loading ...
en Installation instructions
44
6.
Undo the internal setting screw.
7.
Fit the control knob and heat up the oven for 15
minutes.
8.
Turn the controller to the minimum position.
9.
Remove the control knob.
10.
Adjust the internal adjustment screw until a stable
flame is burning correctly.
If required, loosen the adjustment screw to increase
the gas flow. Tighten the adjustment screw to re-
duce the gas flow. The setting is correct when the
height of the small flame is approx.3 to 4mm.
Tighten the adjustment screw in the case of a liquid
connection.
11.
Attach the control knob.
12.
Ensure that the flame does not go out if you quickly
change the gas flow from maximum to minimum
and vice versa, and if you open and close the appli-
ance door.
Replacing grill burner nozzles on appliances
with a grill burner
1.
Undo the screws on the front holder and pull the
burner forwards and out of the gas connection.
On the back wall, the burner is still connected to the
gas supply and the electric ignition.
2.
Carefully place the burner with its front side on the
base of the cooking compartment.
3.
Unscrew the nozzle and replace it with a nozzle that
is suitable for the new gas type.
→"General nozzle table", Page44
4.
Replace the label for the gas type with the new label
that is included with the nozzle set.
5.
To install the burner carry out the instructions in re-
verse order.
General nozzle table
Gas type/burner mbar Nozzle
number
Bypass Power in
watts
Minimum
power in
watts
Maximum consump-
tion
Natural gas G20/oven burner 20 135 (H1) Gap 3600 1200 G20: 352l/h
Natural gas G20/grill burner 20 130 (H3) 3000 G20: 298l/h
Liquid gas butane/propane G30/
G31/oven burner
28 -
30/37
90 (H1) 58 3600 1200 G30: 269g/h
G31: 264g/h
Liquid gas butane/propane G30/
G31/grill burner
28 -
30/37
83 (S) 3000 G30: 218g/h
G31: 214g/h
Nominal operating pressure
Your appliance's nominal operating pressure is:
¡ For natural gas – NG (G20) 20mbar/2.0kPa
¡ For liquid gas – LPG (G30) 30mbar/3.0kPa
¡ For liquid gas – LPG (G31) 37mbar/3.7kPa
You must operate your appliance with these pressure
values. All information on your appliance's rating plate
relates to these pressure values. The manufacturer
shall accept no liability for the functionality and power
of your appliance or for other risks id you operate your
appliance with pressure values that differ from those
specified for your appliance.
Note:If you are operating your appliance with liquid
gas, use a gas pressure regulator. The pressure regu-
lator must be connected and maintained by a licensed
expert.