DuroMax XP10000EHC 10000 Watt Dual Fuel Portable Generator

User Manual - Page 47

For XP10000EHC.

PDF File Manual, 136 pages, Read Online | Download pdf file

XP10000EHC photo
Loading ...
Loading ...
Loading ...
Measure plug gap
Measure the plug gap with a gauge. The gap should be 0.7-0.8
mm (0.028-0.031 in).
4.
Clean and re-gap
Replace spark plug
Replace spark plug cap
If you are re-using the spark plug, use a wire brush to clean
any dirt from around the spark plug base and then re-gap the
spark plug.
Screw the spark plug back into its place on the generator
using the spark plug wrench.
Replace the spark plug cap.
5.
6.
7.
47
Loading ...
Loading ...
Loading ...