Loading ...
Loading ...
Loading ...
Rinnai 20 EHPA_VMA Series 2 Heat Pump OIM
Electrical access is via a 20 mm hole beneath the element
cover for mounting with an approved weatherproof electrical
conduit nipple.
For entry to the element cover remove the two xing screws.
Connect all ACTIVE and NEUTRAL wires in accordance with
the wiring diagram which is also included at the rear of the
element access cover.
Ensure the incoming EARTH wire is securely xed to the earth
post provided on the heater case.
Inspect and ensure that all wiring links are secure prior to
xing the access cover and turning the POWER ON.
To ensure the over-temperature and energy cut-out is set,
press the (red) ‘reset’ button on the Thermostat
NEUTRAL
EARTH
CONTROLLER
CONTROLLER
CONT-
ROLLER
NEUTRAL
Electrical
Connections
Access
IMPORTANT
This appliance MUST NOT be connected via a
switchable or a solar (photovoltaic - PV) power
supply without manufacturer consultation�
The switching of the supplies will place the water
heater into a re-start cycle which reduces the
available heating time and may result in a lack
of hot water
It is recommended this appliance is connected to
either a 24 hour continuous tari󰀨 or an extended
o󰀨-peak power supply (minimum 16 hours per
day, noting that the minimum required running
time is governed by hot water demand and the
climate zone�
If this appliance is replacing an electric water
heater with a capacity of 250 litres (or greater),
then a connection to a 24 hour continuous tari󰀨
supply is recommended�
Disconnect all power prior to installation and commissioning.
This appliance is designed for single phase 240 Volts, AC
mains electrical operation.
INSTALLATION