— 19 —
Installation
STEP 5 (Optional)
(Must be done before Step 6 if converting to Propane)
Liqueed Petroleum (Propane)
Gas Conversion
This appliance can be used with Natural Gas or LP/Propane
Gas. It is shipped from the factory for use with Natural Gas. A
kit for converting to LP gas is supplied with your appliance.
Thekitismarked“FORLP/PROPANEGASCONVERSION”.
u
When the appliance is converted for Liquid Petroleum
(LP) Gas, the LP gas supply is required to provide a
minimum of 10” to a maximum of 12” water column to
the appliance regulator.
Following LP Gas
Conversion, complete
steps:“Adjustingthe
Regulator Pressure”;
“ChangingBurner
Nozzles”;“Adjusting
Burner Flames”; and
“TestingFlameStability”
.
Adjusting the Regulator Pressure
v
Shut off the gas supply to
the appliance by closing
the manual shut-off valve
(see Figure 8). Disconnect
electrical power to the
appliance before servicing. Do
not remove regulator or allow
it to turn during servicing.
w
Unscrew the regulator cap with a wrench (see Figure
9).
x
Remove retainer pin by pulling it out (see Figure 10).
y
Reverse the retainer pin and snap it back into the
regulator cap (see Figure 11).
U
Screw the regulator cap back into the regulator and
re-attach it to the nipple and are union as shown.
DO NOT over-tighten (see Figures 12 and 13).
WARNINGS:
•PleasemakesuretoreadALLsafetyprecautionson
pages 4 to 10.
•Failuretomaketheappropriateconversionafter
Step 4 can result in serious personal injury and
property damage.
•
The conversion must be performed by a qualified
service technician in accordance with the kit instruc-
tions and all local codes and requirements. Failure
to follow instructions could result in serious injury or
property damage. The qualified agency performing this
work assumes responsibility for the conversion.
Joint Joint
Off
On
Manual
Shut off
Valve
Pressure
Regulator
Flare
Union
Flare
Union
Gas Flow
Access
Cap
Figure 8
Figure 9
Figure 12
Figure 13
Figure 10
Figure 11