Warning : Grounding through the neutral conductor
is prohibited for (1) new branch-circuit installations,
(2) mobile homes, (3) recreational vehicles, and (4)
areas where local codes prohibit grounding through the
neutral conductor. Failure to do so can result in fire or
electrical shock.
Prepare minimum 5 ft (1.52 m) of length in order
for dryer to be replaced.
First, strip 3 72 inches (8.9 cm) of outer sheath from
end and strip 1 inch of insulation from each
conductor. ¢
Then, put the hooked shape end of the wire under
the screw of the terminal block (hooked end facing
rightward) and pinch the hook together and tighten
the screw securely.
1. Connect neutral wire (white) of power cord to
center terminal block screw.
2. Connect red and black wires to the left and right
terminal block screws.
3. Make sure that the strain relief screw is tightened.
Be sure that all terminal block nuts are on tight
and power cord is in right position.
Center terminal
block screw (silver)
Neutral grounding
wire (white)
Neutral grounding
wire (white)
Strain relief
ground
connector
If your local codes or ordinances do not allow the
use of a 3-wire connection, or you are installing
your dryer in a mobile home, you must use a
4-wire connection.
(N4-wirereceptacle
EMA type 14-30R)
r 4-prong plug _ Spade terminals with
_ _pturnedends
_Ground prong
_Neutral prong
do4-prongplug _ 3/4 in. (1.9 cm)
proved strain relief
pgng Ring terminals
Center terminal block
screw (silver)
Neutral 9rounding
wire (white)
Neutral wire
(white or center wire)
Strain relief
Green wire of power cord
External ground connector
1. Connect neutral wire (white) of power cord to
center terminal block screw.
2. Connect red and black wires to the left and right
terminal block screws.
3. Connect ground wire (green) of power cord to
external ground screw and move neutral ground
wire of appliance and connect it to center screw.
4. Make sure that the strain relief screw is tightened.
Be sure that all terminal block nuts are on tight
and power cord is in right position.