(Gas dryer only). In addition to the following,
please refer to manual section on Gas Requirements
and Instructions.
I. New stainless steel flexible connector. Use this type of
connector only if allowed by local codes. Use Design AGA
Certified Connector.
2. 118" NtYFPipe Plug (for checking inlet gas pressure)
3. Equipment Shut-Off Valve
Installed within 6' (1.8 m) of dryer.
4. Iron Pipe. Shorter than 20' (6.1 in)
Use 318" pipe.
Longer than 20' (6.1 m) - Use 112"pipe.
5.3/8" N.P.T. Gas Connection.
For instance, using LPGwith LNG orifice will result
in death, fire or explosion. Or using LNGwith LPG
nozzle will not allow the burner toignite'
If needed, orific e conversion should be done by a
qualified service technician and mark or put the
label of the current type of orifice onthe dryer.
If changing the orifice, also adjust the gas valve.
1. Confirm that the type of gas awlilable in your laundry
room is appropriate for the dryer. The dryer is prepared
IBr Natural Gas with a 318" NPT gas connection.
2. Remove the shipping cap fiom the gas connection at the
back of the dryer. Make sure that you don't damage the
threads of the gas connection pipe when you remove the
shipping cap.
3. Connect the dryer to your laundry room's gas supply
using a new flexible stainless steel connector (as noted
below, use a new stainless steel flexible connector if
allowed by your local codes).
4. Securely tighten all connections between the dryer and
your laundry room's gas supply. Turn on your laundry
room's gas supply and check all pipe connections (both
internal and external) IBr gas leaks with a non-corrosive
leak detection fluid. Refer m Part 7 (page 20)
5. For LP (Liquefied Petroleum) gas connection, refer m
this manual's section entitled Gas Requirements and
Instructions.
12
Following are several warnings and instructions
concerning making the electrical connection IBr electric
dryers. More detailed information concerning the
electrical connection is provided in the manual section
entitled Electrical Requirements IBr Electric Dryer.
It is important that you thoroughly review that section
and the remainder of this manual, before taking any
steps to install or use this dryer.
1. Use only a new UL listed No. 10 (copper wire only)
three conductor power supply cord kit rated 240
Volts (minimum) 30 Amperes and labeled as suitable
for usein a clothesdryer.
2. A lbur-wire cord is required Ibr manufactured
(mobile) home installations and where local codes do
not allow grounding of this appliance through
neutral.
3. Electrical Plug Connections.
4. For additional instruction on connecting the dryer to
an electrical power source, please refer to this
manual's section on Electrical Requirements and
Electric Dryer.
Burnerinputrequirements
if yourhouseis locatedat the elevationsup tO
1(
Adjustingburner inputsettingis not needed at this
elevationbecauseA6A certifies this dryerwill not have
any problemwith the BTOrating at this altitude.
if yourhouseisabove f0,000 feet, you arerequired to
adjusta four Percent (4%) reductionof the burner BTU
rating indicated 0n the mode!/sedal rating
WARNING!
Use a new UL listed 30 amp power supply cord
Use a UL approved strain relief
Disconnect power before making electrical
connections
Connect neutral wire (white or center wire) to
center terminal
Ground wire (green or bare wire) must be
connected to green ground connector
Securely tighten all electrical connections
See installation instructions for complete
instructions
Failure to do so can result in fire or electrical
shock