Rinnai 11 DEPH_OIM
CARE AND MAINTENANCE
CARE OF THE HEATER
Due to the ‘natural convection’ operating principle it is normal that some dust and fluff may build up at the air inlet
and air outlet louvres over time. This will reduce operating effectiveness and may result in the appliance overheating
if left for too long.
DO NOT use solvents to clean any parts.
To remove dust and clean the appliance:
1. Unplug the electric plug of the heater from the socket outlet before commencing cleaning.
2. Allow to cool down.
3. Use a vacuum cleaner to remove any dust and fluff from the inlet and outlet louvres.
4. All parts of the heater can be cleaned using a soft, damp cloth with some mild detergent (such as dishwashing
liquid) if required.
5. Ensure the heater is dry before reconnecting to the electricity supply.
ERROR CODES
Your Rinnai panel heater has a self diagnostic capability. If a fault occurs, an Error Code will flash on the two digits
of Digital LED display , a repeating chime will also sound and the appliance will be prevented from operating.
Please quote the error code displayed when enquiring about service, for example:
Error Code
E0 - Temperature sensor disconnection.
SERVICE AND REPAIR
If the electric power cord or plug are damaged, they must be replaced by Rinnai or a Rinnai appointed service agent.
There are no user serviceable parts inside the appliance. All service and repair work must be carried out by persons
competent and permitted by law to do so.
If the heater requires service or repair contact your supplier or Rinnai Australia.
DISPOSAL
Electrical appliances may contain materials which, if handled or disposed off incorrectly, present a hazard to humans
or the environment.
DO NOT dispose of your old appliance with your household waste. Dispose of your old appliance at your local
community waste collection / recycling centre and ensure it presents no danger to children whilst being stored for
disposal.