Installation
www.bora.com
21
Fig. 6.6 Return ow aperture in the plinth area
[1] Return flow aperture (total opening cross-section ≥500 cm²)
[2] Return flow of recirculated air
Ensure that the return flow aperture is large enough.
6.5 Worktop cut-out
Worktop overhang
50x
Fig. 6.7 Worktop overhang
Please note the worktop overhang x when creating
the worktop cut-out. Applies to flush installation and
surface mounting.
Create the worktop cut-out taking into account the
specified cut-out dimensions.
Make sure that the cutting surfaces of the worktops
are properly sealed.
Comply with the instructions of the worktop
manufacturer.
6.4.3 Minimum unit dimensions for X Pure
(PUXA, PUXU)
199
≥600
≥900
Fig. 6.4 X Pure minimum unit dimensions
6.4.4 Minimum unit dimensions for Pure
(PURA, PURU)
≥600
199
≥800
Fig. 6.5 Pure minimum unit dimensions
6.4.5 Return flow of recirculated air in
appliances in recirculation mode
In the case of recirculation appliances there must be a
return flow aperture in the kitchen units ≥500 cm
2
.
For recirculation, the necessary return flow aperture can
be created using a shortened plinth. A slatted plinth with
at least the minimum opening cross-section can also be
used.