ELECTRICAL CONNECTION
The installation of this appliance and the connection to the electrical network should be
entrusted only to an electrician who is aware of the normative regulations and respects
them scrupulously.
The electrical parts should always be protected after the building-in.
The necessary data of connection are on the stickers placed on the bottom of the
appliance.
The appliance should be separated from the mains by using a multipolar circuit breaker.
The contact opening must be at least 3 mm.
The electrical circuit must be separated from the mains by adapted devices, such as circuit
breakers, fuses or (differential) contactors.
If the electrical supply is restricted, means of all-pole disconnection must be accessible
and incorporated in the fixed wiring in accordance with the wiring rules.
The inlet hose must be positioned so that it does not touch any of the hot parts of the hob
or oven.
Caution!
This appliance can only be connected to a network 230 V~ 50/60 Hz.
You should always connect the earth wire.
Respect the connection diagram.
Use the connecting cable that is attached to the device.
The green / yellow wire corresponds to the earth wire, the blue wire corresponds to the neutral
wire and the brown wire correspond to the phase.
* calculated with the simultaneous factor following the standard EN 60 335-2-6/1990
Connection of the hob
Monophase 230V~1P+N
Attach the earth to the terminal “earth”, the neutral N to terminal N, the Phase L1 to one of the
terminals L1.
Caution! Be careful to correctly engage and tighten the cables.
Mains Cable diameter Cable Protection calibre
230V~ 1 Phase + N 50/60Hz
3 x 1,5 mm²
H 05 VV - F
H 05 RR - F
16 A *
We cannot be held responsible for any incident resulting from incorrect connection or
which could arise from the use of an appliance which has not been earthed or has been
equipped with a faulty earth connection.