Maintenance
MAINTENANCE
BOILER CLEANING (recommended every 6 months)
Always disconnect the power supply cord and ensure that the
equipment is completely cool and the boiler contains no water.
Disconnect the iron from the steam supply.
Slowly unscrew the safety cap and remove it.
Incline the board (1) and unscrew the boiler unit. We recommend
you begin carefully from the lower screws, making sure that the
boiler unit does not fall.
Using the bottle ll the boiler with 0.8 litres of water. Close the cap
and shake vigorously then unscrew the cap and tip the liquid into
the sink.
Repeat the operation, two or three times.
When you have nished reassemble the boiler unit to the board
ensuring that it is properly connected.
Note: If you have damaged the boiler, or it has developed a fault,
disassemble it as described above and either take it or send it to an
authorised repair centre.
Important!
Never pour any kind of detergents or decalciers into the generator.
Never perform Maintenance when the steam generator is under
pressure. Perform maintenance only when the equipment is
completely cooled.