13
NOTES : *1.Rating conditions (cooling)-Indoor : D.B. 26.7°C(80°F), W.B. 19.4°C(67°F) Outdoor : D.B. 35°C(95°F), W.B. 23.9°C(75°F)
(heating)-Indoor : D.B. 21.1°C(70°F), W.B. 15.6°C(60°F) Outdoor : D.B. 8.3°C(47°F), W.B. 6.1°C(43°F)
*2.Conditions (heating)-Indoor : D.B. 21.1°C(70°F), W.B. 15.6°C(60°F) Outdoor : D.B. -8.3°C(17°F), W.B. -9.4°C(15°F)
*3.Conditions (heating)-Indoor : D.B. 21.1°C(70°F), W.B. 15.6°C(60°F) Outdoor : D.B. -15°C(5°F), W.B. -15°C(5°F)
Operating range
Indoor intake air temperature
D.B. 32°C(90°F), W.B. 23°C(73°F)
D.B. 19°C(66°F), W.B. 15°C(59°F)
D.B. 28°C(83°F)
D.B. 17°C(63°F)
Outdoor intake air temperature
D.B. 46°C(115°F)
D.B. -18°C(0°F)*
D.B. 21.1°C(70°F), W.B. 15°C(59°F)
D.B. -25°C(-13°F), W.B. -25°C(-13°F)
Cooling
Heating
Maximum
Minimum
Maximum
Minimum
* In case that the wind baffle is installed. (In case that the wind baffle is not installed, the minimum temperature will be -5°C(23°F)DB.)
Model name Indoor unit
PCA-A36KA
Outdoor unit
PUZ-HA36NHA2
Cooling Max. Capacity Btu/h
Rated Capacity Btu/h
Min. Capacity Btu/h
18,000
Total Input W
EER Btu/h/W
SEER Btu/h/W
Moisture Removal Pints/h
*1 SHF
Heating Max. Capacity Btu/h
40,000
Rated Capacity Btu/h
38,000
Min. Capacity Btu/h
18,000
Total Input W
3,270
COP W/W
3.41
10.3 / 8.2
*1 HSPF(IV/V) Btu/h/W
Heating at 17°F(-8.3°C) Max. Capacity Btu/h
38,000
Total Input W
5,720
*2 COP W/W
1.95
Heating at 5°F(-15°C) Max. Capacity Btu/h
38,000
Total Input W
6,550
*3 COP W/W
1.70
PCA-A30KA
PUZ-HA30NHA2
30,000
30,000
18,000
2,480
12.1
16.1
8.3
0.69
34,000
32,000
18,000
2,990
3.14
9.3 / 7.2
32,000
5,170
1.81
32,000
5,830
1.61
Power supply Phase, Cycle, Voltage
1phase, 60Hz, 208/230V
Breaker size A
30
Voltage Indoor - Outdoor S1 - S2
AC208/230V
Indoor - Outdoor S2 - S3
DC24V
Indoor - Remote Controller
DC12V
Indoor unit MCA A
2
MOCP A
15
Fan Motor F.L.A. 0.97
Fan Motor Output W
160
Airflow DRY (Lo-M2-M1-Hi) CMM
22-24-26-28
Airflow WET (Lo-M2-M1-Hi) CMM
20-22-24-26
Airflow DRY (Lo-M2-M1-Hi) CFM
775-850-920-990
Airflow WET (Lo-M2-M1-Hi) CFM
705-775-850-920
1
0.54
95
16-17-18-20
15-16-17-19
565-600-635-705
530-565-600-670
External pressure Pa
0
Sound level (Lo-M2-M1-Hi) dB(A)
37-39-41-4335-37-39-41
External finish (Grille)
White Munsell 6.4Y 8.9/0.4
Dimension Unit (Grille) W : mm[inch]
1280 [50-3/8]
D : mm[inch]
680 [26-3/4]
H : mm[inch]
Weight Unit(Grille) kg
36
230 [9-1/16]
32
Weight Unit(Grille) lbs
79
Field drain pipe size mm[inch]
O.D. 26 [1-1/32]
Remote Controller
Attached in Grille
Outdoor unit MCA A
28
MOCP A
40
Fan Motor F.L.A.
0.4 + 0.4
Fan Motor Output W
60 + 60
Compressor Type
ANB33FJEMT
R.L.A.
18
L.R.A.
27.5
Air flow CMM[CFM]
100[3,530]
Refrigerant Control
Electronic Expansion Valve
Defrost Method Reverse Cycle
Sound level at cooling dB(A)
52
Sound level at heating dB(A)
53
External finish Ivory Munsell 3Y 7.8/1.1
Dimension W : mm[inch]
950 [37-3/8]
D : mm[inch]
330 + 30 [13 + 1-3/16]
H : mm[inch]
1,350 [53-1/8]
Weight kg[lbs]
120 [265]
Refrigerant Type
R410A
Charge kg[lbs, oz]
5.5 [12 lbs]
Oil L[oz]
1.4(FV50S) [45]
Refrigerant pipe size Gas side O.D. mm[inch]
15.88 [5/8]
Liquid side O.D. mm[inch]
9.52 [3/8]
Refrigerant pipe length Height difference
Max.30m [Max.100ft]
Length
Max.75m [Max.245ft]
Refrigerant Piping Not Supplied
Connection Method
Flared
71
1600 [63]
36,000
34,000
2,810
12.1
16.6
8.2
0.73
DOCS1415revA.indd13DOCS1415revA.indd13 10.8.254:09:19PM10.8.254:09:19PM