Loading ...
Loading ...
Loading ...
32
Cleaning the Condenser
The Condenser requires periodic cleaning
(recommended once per month under normal drying
conditions). The frequency of cleaning depends on the
amount and type loads being dried.
To clean the Condenser:
1.
If the dryer is hot, run on Air Fluff/No Heat program to
allow the dryer to cool down.
2.
Residual water may escape, place an absorbent cloth
under the maintenance flap.
3.
Unlock the maintenance flap and open it completely.
4.
Turn both locking levers towards each other.
5.
Pull out the Condenser cap.
6.
Remove the Condenser.
NOTICE: Do not damage the Condenser! Clean with
warm water only. Do not use hard or sharp edged
objects!
7.
Rinse the Condenser and the cap on all sides with a
jet of water to completely remove all of the lint and
fluff.
8.
Remove all lint and fluff from the seals on the dryer
and Condenser.
9.
Allow the cap and the Condenser to dry fully.
10.
First insert the Condenser, then the cap.
11.
Turn back both locking levers.
12.
Close the maintenance flap until it locks into position.
13.
Look in the Troubleshooting table to reset the
maintenance indication.
~ Troubleshooting; Page 34
Loading ...
Loading ...
Loading ...