Performance Data Sheet
SmartWater Filtration System
GSWF Cartridge
This systemhas been testedaccordingto NSF/ANS142/53forreductionof the substances listed below
Theconcentrationof the indicated substancesin water entering thesystemwas reducedto a concentration
less thanorequal to thepermissible limit for water leavingthe system, as specified in NSF/ANS/42_3.*
(100%safety factors built in for unmetered usage)
Pa]l-al_leter
(:hlorine
"I & ()
]:'arli( ulale**
Parameter
Turbidity
(Xqs
Le_d at pH 6.5
Le_d at pH 8.5
Lindane
Atrazine
USEPA
MCL
USEPA
lnfluent
Average
1.845 mgiL
143,333#imL
lnfluent
Standard No. 42: Aesthetic Effects
[_ffluent Challenge
Collcentr;t|iOll
2.0 lngiL+10%
al leat 10J)00 pardcles/rnL
Stmldard No. 5.'4: Health Effects
[nfluent ChMlenge Effluent
Effluent
Average Maximtan
< 0.05 mgiL tl.tl5mg/L
29.83 #/mE 140 #/mE
% Reduction
Average Mi_mntan
> 97.29% 96.43%
99.98!', 99.91 ¢;,
_, Reduction
Min. Reqtdred
Reduction
> 50%
>85%
Min. Req_red
MCL
1 NT[ ***
99.95_ Reduction
0.015 lngiL
(1.015 mg/L
0.0002 lngit
0.003 mgiL
Average
10.3 NT[ **"
200,000 #iL
0.15 lngiL
(1.14 lngiL
(1.0216 rag/L
0.008 mg/L
Concellh_d|ioil
l+l NT[ **"
Minimum50,000L
0.15 mg/L+10%
0.15 lng/L+10%
0.002 mgiL+l()!'_
0.009 mgiL+l(l%
Average
0.10G N'[-[
0
< (}.01}1 lng/L
(}.(}0l mgiL
<0.00002 mgiL
< 0.002 lngiL
Maxim(ml
0.14 NT[
0
< 0.00l lngiL
0.003 mg/L
< 0.00002 mgiL
< 0.002 lngiL
Average
98.97%
> 99.9971
> 11q.3371
> 99.29!'1
99.(}7%
> 76.12_:;
Mi_immn Reduction
98.61% 0.5 NT[
> 99.9{E:; > 99.9571
> 99.3'3_:; 0.01(1 lngiL
97.86% 0.010 lngiL
98.75% 0.0002 mgiL
> 66.67(:i 0.003 lngiL
Testedusinga flow rate of O.5gpm;pressureof 6Opsig pHof 7.5_+0,5;temp,0f68°_+ 5°F(20°_+3°C1
.....Measurementin Particles/m/.Particlesusedwere0,5-1microns
NTU=NephelometricTurbidityunits
Operating Specifications
[] Caparity: (ertified fin" up to 750 gallons (2,838 l); up to six months
[] Pressure requirement: 40-120 psi (2.8-8.2 bar)
[] Temperature: 33-100°F (0.6-38°(:)
[] Flow rate: 0.5 gpm (1.9 lpm)
General/nstallation/Operetion/Maintenance Requirements
[] Flush ne_,_ cartridge at hdl flow for 3 minutes to l)m'ge, out trapped air.
[] Replace cartridge when flow becomes too slow.
Special Notices
[] Installation instru(tions, parts and service awfilability, and standm'd win'rarity are included with the product when shipI)ed.
[] This drinking water s}:stem must be maintained according to manufilcturer's instructions, including replacement of filter
cartridges.
[] Do not use with water that is microbiologically unsate or of unknown quality without adequate disinfection beflwe or
aiter the system. Systems certified fl)r cyst reduction may be used on disinlected water that may contain filterable cysts.
[] The contaminants or other substances removed or reduced by this water treatment system are not necessarily in
Vo/Ir water.
[] Check fin" compliance with the state and local laws and regulations.
[] Note that while the testing was perflwmed trader standard laboratm y conditions, actual performance may w_ry. Systems
must be installed and operated in accordance with manufhcturer's recommended procedm'es and guidelines.
Svsteln lest((1 all<] c(rtifi((1 by NSF International agaillSl Standard 42 for th( r((luction of
chlorin(, tast( an(1 odor, particular( Class ] a (1 S a M, d :)_ for the re(luclion of" (:}'st,
lead, Lindane, Atrazine and mrbidily.
Malltlt}l(:ltll-e(l t()1-: (;elleral Elecu-i( (]Ollll)all}, Ixmisville, K%_ 40225