OPERATION MANUAL - Page 4

For AS53TCCHRA-SET. Also, The document are for others Haier models: AS09TACHRA, AS12TBCHRA, AS18TCCHRA, AS24TECHRA, AS26TACHRA, AS35TBCHRA, AS53TCCHRA, AS71TECHRA

Loading ...
Loading ...
Loading ...
Operation
POWER/SOFT Operation
Emergency Operation:
16 , do not use it in the normal operation.
Test operation:
Use this switch in the test operation when the room temperature is below
Continue to press the test operation switch for more
than 5 seconds. After you hear the “Pi” sound twice,
release your finger from the switch: the cooling
operation starts with the air flow speed “Hi”.
Test operation switch is the same as emergency switch.
Emergency operation and test operation
Use this operation only when the remote controller
is defective or lost.
When the emergency operation switch is
pressed,the" Pi "sound is heard once, which means
the start of this operation.
In this operation, the system automatically selects
the operation modes,cooling or fan or heat,according
to the room temperature.
It is not possible to operate in dry mode.
Room
temperature
Operation
mode
Designated
temperature
Timer
mode
Air flow
ABOVE 23
O
C
BELOW 23
O
C
COOLING
HEAT
23
O
C
26
O
C
NO
NO
AUTOMATIC
AUTOMATIC
Pi
(Cooling only uint
Room temperature
Operation
mode
Designated
temperature
Timer
mode
Air flow
BELOW 23
O
C
FAN
26
O
C
NO
AUTOMATIC
Pi Pi
After 30 minutes, test operation ends automatically.
(This function is unavailable on some models.)
3
(1)
POWER Operation
(2)
QUIET Operation
Note
When you need rapid heating or cooling, you can use this function.
You can use this function when silence is needed for rest or reading.
During POWER operation, in rapid COOL mode ,
the room
will show inhomogeneous temperature distribution.
Long period QUIET operation will cause effect of not too
cool or not too warm.
Press QUIET button, the remote controller will show ,
and then achieve to the quiet function. Press again this
QUIET button , the quiet function will be cancelled.
Press button to enter additional options, when cycle
display to , will flashand then press ,enter to
power function. When cancel the function, please enter
additional options again and to cancel power function.
1.After unit starts, select your desired operation mode.
2.Press TIMER button to change TIMER mode. Every
time the button is pressed, display changes as follows:
Remote controller:
Then select your desired TIMER mode (TIMER ON or
TIMER OFF or TIMER ON-OFF). " "or " "will flash.
Timer On/Off On-Off Operation
BLANK
TIMER ON TIMER OFF TIMER ON-OFF
3.Press / button to set time.
It can be adjusted within 24 hours.
Hints:
After replacing batteries or a power failure happens, time
setting should be reset.
According to the Time setting sequence of TIMER ON or
TIMER OFF, either Start-Stop or Stop-Start can be achieved.
TIMER OFF-ON
0.5h
0.5h 0.5h
0.5h
Press the button for each time, setting time in the first
12 hours increased by 0.5 hour every time, after 12
hours,increased by 1 hour every time.
Press the button for each time, settiing time in the first
12 hours decreased by 0.5 hour every time, after 12
hours,decreased by 1 hour every time.
After adjust the time,press button and confirm the
time ON or OFF button will not flash any more.
4.Confirm timer setting
5.Cancel timer setting
Press the button by times until the time display
eliminated.
Self Clean Operation
Functional description: the purpose of this function is to
clean the evaporator.
Entry and exit Press self clean button to enter this
function, then it will display "CL" on the panel of the indoor
unit and also on the remote controller. After running 20-30
minutes, this function will exit automatically when the " Pi "
sound is heard twice, then the unit returns to original state.
Under operation process of self clean, pressing the button
repeatedly has no effect and the function will not exit, but
pressing the power off button and other mode button can
make it exit.